Patton electronic 3088 Benutzerhandbuch

Seite von 48
 
13
 
Configuration Reset to Factory Defaults
 
To recover from a forgotten password, the user may reset the unit to its 
factory configuration. After seeing the “Reset Mode” message, the user 
should type the ‘*’ key. This will result in a ‘:’ prompt. At the prompt, the 
user should enter the command reset. This will restore the unit to the fac-
tory configuration. The unit can then be restarted with the settings 
in place.
 
4.3  DIP SWITCH SETTINGS
 
The 3088 can be configured with DIP switches. If the DIP switches are 
set to anything other than all ON, then the unit will be in DIP switch con-
figuration. In DIP switch configuration, the console and EOC cannot be 
used to change configuration.
The following table describes the DIP switch functions.
 
Position
Function
Factory Default
 
S1-8
TX Clock
ON
Normal
S1-7
Data Rate
ON
256K
S1-6
ON
S1-5
ON
S1-4
ON
S1-3
ON
S1-2
OFF
S1-1
OFF
S2-8
Reserved
OFF
S2-7
OFF
S2-6
DTE Loops
OFF
Disabled
S2-5
Clock Mode
OFF
Receive-
Recover
S2-4
ON
S2-3
Annex
OFF
Annex B
S2-2
Line Probe
ON
Disabled
S2-1
Front Panel Switches
OFF
Enabled