One  side  of  the  enclosure  shall  be  completely 
1. 
open.
Enclosures that have four sides, complete with a 
2. 
top and bottom:
At least two ventilation openings at cylinder 
a. 
valve level shall be provided in the sidewall, 
equally  sized,  spaced  at  180º  (3.14  rad), 
and  unobstructed.  Each  opening  shall  have 
a total free area of not less than one square 
inch  per  pound  (7.1  cm²/kg)  of  stored  fuel 
capacity, and not less than a total free area 
of 10 square inches (64.5 cm²).
Ventilation  openings  shall  be  provided  at 
b. 
floor level and shall have a total free area of 
not less than one square inch per pound (7.1 
cm²/kg) of stored fuel capacity and not less 
than  a  total  free  area  of  10  square  inches 
(64.5cm²).    If  ventilation  openings  at  floor 
level are in a sidewall, there shall be at least 
two openings.  The bottom of the openings 
shall be at floor level and the upper edge no 
more than 5 inches (127 mm) above the floor. 
The openings shall be equally sized, spaced 
at 180º (3.14 rad) and unobstructed.
Every  opening  shall  have  minimum 
c. 
dimensions so as to permit the entrance of a 
1/8 inch (3.2 mm) diameter rod.
Transporting and Storing LP Gas
Transport  only  one  cylinder  at  a  time.  Ensure  the 
cylinder  is  secured  in  an  upright  position  with  the 
control  valve  turned  off  and  the  dust  cap  in  place. 
Store cylinders outdoors and out of reach of children. 
Do not store cylinders in a building, garage, or any 
other enclosed area.
LP Gas
Tank Requirements
For  plumbed-in  LP  installation,  use  a 
convertible  regulator  and  set  it  for  LP 
gas. 
Maximum  line  pressure  for  plumbed-in 
propane is 14” WC (3.5 kPa). Minimum 
line pressure for propane is 11” WC.
The  grill  unit  must  be  used  with  the 
gas  pressure  regulator.  The  regulator 
will control and maintain a uniform gas 
pressure  in  the  manifold.  The  burner 
orifices have been sized for the gas pressure delivered 
by the regulator.
WARNING:  Attempting  to  operate  the  grill  unit 
without  the  gas  regulator  installed  could  cause  an 
explosion and possible death.
Cylinder Specification
Any LP gas supply cylinder used with this grill must 
be:
Constructed  and  marked  in  accordance  with 
• 
the  Specifications  for  LP-Gas  Cylinders 
of  the  U.S.  Department  of  Transportation 
or  the  National  Standard  of  Canada,  CAN/
CSA-B339,  Cylinders,  Spheres  and  Tubes 
for  Transportation  of  Dangerous  Goods; 
and Commission, as applicable.
Approximately  12  inches  in  diameter  and  18 
• 
inches high.
The maximum fuel capacity is 20 lbs. of propane, or 5 
gallons.  Full cylinder weight should be approximately 
38 lbs. (43.7 lbs. nominal water capacity.) Never fill 
the cylinder beyond 80% full.
Place  the  dust  cap  on  the  cylinder  valve  outlet 
whenever the cylinder is not in use. Only install the 
type of dust cap on the cylinder valve outlet that is 
provided with the cylinder valve. Other types of caps 
or plugs may result in leakage of propane.
LP Gas Hook Up
An enclosure for an LP gas cylinder shall be vented by 
openings at the level of the cylinder valve and at floor 
level. The effectiveness of the openings for purposes 
of  ventilation  shall  be  determined  with  the  LP-gas 
supply cylinder in place.  This shall be accomplished 
in one of the following manners: