Pfaff 1183 Benutzerhandbuch

Seite von 42
 
 
Care and maintenance
 
33
10
.05
 Parameter 
settings
Parameter settings are described in the separate operations manual for 
the drive, and may only be changed by qualifi  ed technicians!
10
.05.01 
Parameter list for control unit P40 ED and P40 PD2
Group
P
arameter
Description
User lever
S
et
ting range
S
et value P40 ED
S
et value P40 PD2
1
105
Speed for start backtackl
B, C
300 - 2000
1200
1200
110
Speed for end backtack
B, C
300 - 2000
1200
1200
6
606
Speed min
B, C
30 - 300
180
180
607
Speed max.
B, C
300 - 6000
6
609
Cutting speed 1
B, C
60 - 300
180
180
660
Bobbin thread control 
0 = off, 1 = thread monitor, 
2 = reverse counter
A, B, 
C
0 - 2
0
-
668
Thread wiper/thread blower
1 = on; 0 = off
B, C
0 - 1
0
-
7
700
Needle position 0 
(needle reference position
B, C
0 -255
*
*
702
Needle position 1 (needle lowered)
B, C
0 - 255
90
90
703
Needle position 2 (take-up lever raised) 
B, C
0 - 255
236
236
705
Needle position 5 (end cutting signal 1)
B, C
0 - 255
200
200
706
Needle position 5 (start cutting signal 2)
B, C
0 - 255
136
136
707
Needle position 9 (start thread tension 
release/start thread catcher)
B, C
0 - 255
164
164
760
Multiplier for the fi xed value (200) 
stitch count
A,B, 
C
0 - 250
5
-
797
Hardwaretest (OFF / ON ),
B, C
OFF
OFF
799
Selected machine class
C
1 - 3
1
2
8
800
Rotating direction of the motor
C
0 - 1
0
0
802
Main drive reduction ratio
0 = 1:1, 1 = variable
C
0 - 1
-
0
V
 
See Chapter 3 Specifi cations
*