Maytag mdg-75 Benutzerhandbuch

Seite von 63
26
2. Technical Gas Data
a. Gas Specifications
b. Gas Connections:
Inlet connection ------------ 3/4-inch N.P.T.
Inlet supply size ------------ 3/4-inch N.P.T. (minimum)
Btu/hr input (per dryer) --- 200,000 (50,400 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer’s gas valve’s internal regulator.  Incoming supply pressure must
be 
 consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb)
water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be  regulated upstream of the dryer.  The pressure measured at each gas
valve pressure tap must be  a consistent 10.5 inches (26.1 mb) water column.  There is no regulator
or regulation provided in an L.P. dryer.  The water column pressure must be  regulated at the source
(L.P. tank) or an external regulator must be  added to each dryer.
TYPE OF GAS
L.P.
Conversion
Kit
Part Number
MODEL
NUMBER
BTU
Per Hour
Rating
kcal/hr
Rating
Natural
Liquid Propane
Qty.
D.M.S.*
Part
Number
Qty. D.M.S.*
Part
Number
MDG-75
200,000
50,400
4
#
29
140820
4
#47
140805
881231
Shaded area is stated in metric equivalent
* Drill Material Size (D.M.S.) equivalents are as follows:
TYPE OF GAS
NATURAL
LIQUID PROPANE
  Manifold Pressure*
3.5 inches W.C.
8.7 mb
10.5 inches W.C.
26.1 mb
  In-Line Pressure
6.0 - 12.0 inches W.C.
14.92 - 29.9 mb
11.0 inches W.C.
27.4 mb
Shaded areas are stated in metric equivalents
Natural Gas ...............  #29 = 0.1360” (3.4544 mm).