Put power supply cord through the strain relief. Be sure that 
the wire insulation on the power supply cord is inside the 
strain relief. The strain relief should have a tight fit with the 
dryer cabinet and be in a horizontal position. Do not further 
tighten strain relief screws at this point.   
Style 2: Direct wire strain relief
Unscrew the removable conduit connector and any screws 
from a  " (19 mm) UL listed strain relief (UL marking on strain 
relief). Put the threaded section of the strain relief through the 
hole below the terminal block opening. Reaching inside the 
terminal block opening, screw the removable conduit 
connector onto the strain relief threads.  
Put direct wire cable through the strain relief. The strain relief 
should have a tight fit with the dryer cabinet and be in a 
horizontal position. Tighten strain relief screw against the 
direct wire cable. 
4. Now complete installation following instructions for your type 
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
*If local codes do not permit the connection of a cabinet-ground 
conductor to the neutral wire, go to “Optional 3-wire connection” 
section.
4-wire connection: Power supply cord 
IMPORTANT: A 4-wire connection is required for all mobile 
homes and where local codes do not permit the use of 3-wire 
connections.
A. Removable conduit connector
B. Hole below terminal block opening
C. Strain relief threads
A
B
C
If your home has:
And you will be 
connecting to:
Go to Section
4-wire receptacle
(NEMA Type 14-30R)
A UL listed,
120/240 volt 
minimum, 
30-amp, dryer 
power supply 
cord*
4-wire connection:
Power supply cord
4-wire direct
A fused 
disconnect or 
circuit breaker 
box*
4-wire connection:
Direct Wire
3-wire receptacle
(NEMA type 10-30R)
A UL listed, 
120/240 volt 
minimum, 
30-amp, dryer 
power supply 
cord*
3-wire connection:
Power supply cord
3-wire direct
A fused 
disconnect or 
circuit breaker 
box*
3-wire connection:
Direct Wire
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F.
" (19 mm) UL listed strain relief
G. Ring terminals
(127 mm)
5"
(89 mm)
3 "
A
B
C
D
E
F
G
3
4
1
2
3
4