GENERATOR OUTPUT VOLTAGE/KW-60Hz
Rated AMP
Rated AMP
120/240V, 1-phase, 1.0 pf
150
625
120
500
120/208V, 3-phase, 0.8 pf
150
520
120
416
120/240V, 3-phase, 0.8 pf
150
451
120
361
277/480V, 3-phase, 0.8 pf
150
226
120
180
600V, 3-phase, 0.8 pf
150
180
120
144
GENERATOR OUTPUT VOLTAGE/KVA-50Hz
Rated AMP
Rated AMP
110/220V, 1-phase, 1.0 pf
120
545
96
436
115/200V, 3-phase, 0.8 pf
150
433
120
346
100/200V, 3-phase, 0.8 pf
150
433
120
346
231/400V, 3-phase, 0.8 pf
150
217
120
173
480V, 3-phase, 0.8 pf
150
180
120
144
MOTOR STARTING KVA
Maximum at 35% instantaneous voltage dip
231/240V
400/480V
231/240V
400/480V
with standard alternator; 50/60 Hz
390
405
390
405
with optional alternator; 50/60 Hz
325
338
325
338
FUEL
Fuel consumption—60 Hz
Load
25%
50%
75%
100%
25%
50%
75%
100%
liters/hr.
9.3
17.3
25.1
32.6
7.4
13.8
20.1
26.0
gal./hr.
2.5
4.6
6.6
8.6
2.0
3.6
5.3
6.9
Fuel consumption—50 Hz
liters/hr.
7.4
13.8
20.1
26.0
5.9
11.0
16.0
20.8
gal./hr.
2.0
3.6
5.3
6.9
1.6
2.9
4.2
5.5
COOLING
Coolant  capacity
System - lit. (gal)
19.0 (5.0)
19.0 (5.0)
Engine - lit. (gal)
9.8  (2.6)
9.8  (2.6)
Radiator - lit. (gal)
9.2 (2.4)
9.2 (2.4)
Coolant flow/min.
60 Hz - lit. (gal)
159.0  (42.0)
159.0  (42.0)
50 Hz - lit. (gal)
132.5  (35.0)
132.5  (35.0)
Heat rejection to coolant @ full load
BTU/hr.
344,700
275,760
Air to radiator in
60 Hz - m
3
/min. (cfm)
159 (5,600)
159 (5,600)
enclosed unit
50 Hz - m
3
/min. (cfm)
132 (4,667)
132 (4,667)
Max. external pressure drop on radiator
in. H
2
O
0.5
0.5
Max. air temperature to radiator
°C (°F)
48.9 (120)
48.9 (120)
Max. ambient temperature
°C (°F)
43.3 (110)
43.3 (110)
COMBUSTION AIR REQUIREMENTS
Flow at rated power
60 Hz - m
3
/min.  (cfm)
14.2 (501.0)
11.3 (400.8)
50 Hz - m
3
/min. (cfm)
11.3 (398.9)
9.0 (319.2)
EXHAUST
Exhaust flow at rated output  60 Hz - 
m
3
/min. (cfm)
38.6 (1362)
30.9 (1090)
50 Hz - m
3
/min. (cfm)
30.7 (1085)
24.6 (868)
Max recommended back pressure  in. Hg (kPa)
5.1 (1.5)
5.1 (1.5)
Exhaust temperature at rated output
°C (°F)
538 (1000)
538 (1000)
Exhaust outlet size
mm. (in.)
127 (5.0)
127 (5.0)
ENGINE
Rated RPM
60 Hz / 50 Hz
1800 / 1500
1800 / 1500
HP at rated KW
60 Hz / 50 Hz
221 / 176
178 / 141
Piston speed
60 Hz - m./sec. (ft./min.)
7.8 (1535)
7.8 (1535)
50 Hz - m./sec. (ft./min.)
6.5 (1280)
6.5 (1280)
BMEP
60 Hz / 50 Hz - psi
223 / 213
180 / 171
DERATION FACTORS
Temperature
-3.5% for every 10
o
C above - °C
40
40
-2.77% for every 10
o
F above - °F
104
104
Altitude
-1.1% for every 100 m above - m
1066
1066
-3.5% for every 1000 ft. above - ft.
3500
3500
OPERATING DATA
NOTE:  Consult your
Generac dealer for
additional voltages.
NOTE:  Consult your
Generac dealer for
additional voltage
SD150