cortech datalog 3-sony hsr-1 Benutzerhandbuch

Seite von 6
Datalog 
3
 - SMS Software Application Sheet
Sony HSR-1P - Page 1 of
 
6
CORTECH DEVELOPMENTS LTD
SONY HSR-1P
DIGITAL CCTV  RECORDER
Introduction
The Datalog 3 Alarm management software has been modified to incorporate a driver to
communicate with the Sony HSR-1P Digital Surveillance Recorder.
The driver Includes:
1.    A set-up option allowing up to 3, out of the maximum 16, camera inputs to be assigned to a
Datalog zone when that zone is in alarm.
2.  A user option available from a Main screen button or menu item to show an on-screen panel
with buttons and display to select Video recorder functions and display status. The panel
includes search routines either by alarm recording number, or time and date.
Installation
The Sony HSR-1P Digital Surveillance recorder should be connected to the Datalog 3 system
using a cable with the following connections:
The Data format is 9600baud, 8 data bits, 1 Stop bit, No Parity which is the default setting on the
Sony HSR-1P
.
Downloaded from:
 http://www.guardianalarms.net