Lennox gas stove Benutzerhandbuch

Seite von 30
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
VIS
ALCOVE DIMENSIONS -  DIMENSIONS – ALCOVE
MAXIMUM DEPTH / PROFONDEUR MAXIMUM 35”(889mm)
MINIMUM WIDTH / LARGEUR MAXIMUM 51”(1295mm)
MINIMUM HEIGHT / HAUTEUR MAXIMUM 46”(1168mm)
SEE OWNER’S MANUAL FOR OTHER ALCOVE 
CLEARANCE CONFIGURATIONS.
RÉFÉREZ VOUS AU MANUEL D’INSTALLATION 
POUR TOUT AUTRE DÉGAGEMENT REQUIS.
HEARTH PROTECTION
SEE INSTRUCTION MANUAL.
PROTECTIONS AU PLANCHER : RÉFÉREZ 
VOUS AU MANUEL D’INSTALLATION.
* 16.5” (1295Mm) to sidewall in an alcove 
* Dégagement des matériaux 
  Combustible pour les murs de côté 
  Dans une alcôve est 16.5 Po (1295mm)
  De chaque côté.
MINIMUM CLEARANCES TO COMBUSTIBLES IN INCHES
DÉGAGEMENTS AUX COMBUSTIBLES - POUCES
2"
(51mm)
*15"
(381mm)
Co
m
bu
sti
ble
 W
all
Mur Combustible
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES.
TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91.
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY.  IF NOT, FOLLOW THE CURRENT ANSI 
Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA  B149.1-LATEST EDITION (CANADA)
 AND SAFETY STANDARD, TITLE 24 CFR, 
PART 3280 FOR MOBILE HOMES.  ALSO, APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S 
INSTALLATION INSTRUCTIONS.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN 
AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. 
SEE OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A 
CERTIFIED KIT IS USED.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. 
IF NOT, FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST 
EDITION (CANADA).
VENTING: THIS APPLIANCE  MUST  BE  PROPERLY  CONNECTED  TO A  VENTING  SYSTEM  IN ACCORDANCE  WITH  THE 
MANUFACTURER’S INSTRUCTIONS. SEE MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR APPROVED PIPE BRANDS 
AND PIPE SEALING PROCEDURES.
FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 1,000 
FT (405 M).
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.
Part No./ No. Pièce #36242 Rev. A, 05/2007
DO NOT REMOVE OR COVER THIS LABEL
MADE IN U.S.A.
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP 
CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS 
AWAY. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING 
INSTRUCTIONS ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS 
APPLIANCE ONLY. DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. 
REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN 
CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED 
WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED 
INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.
ALCOVE OR PARALLEL / 
POSITION PARALLÈLE OU 
POSITION DE L'ALCÔVE
CORNER / 
POSITION
EN COIN
MANUFACTURED BY / FABRIQUÉ PAR:
LENNOX HEARTH PRODUCTS
PO BOX 987
AUBURN, WA., USA 98071
MODEL
VISION™
MODÈLE
Report No. / Número de Rapport
050-S-16b-5
SERIAL
 NO.
FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.
CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT 
CETTE ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.
RATINGS
Vision 35 (VIS35)
Vision 25 (VIS25)
NATURAL GAS
LP GAS
NATURAL GAS
LP GAS
MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*
35,000/23,000
35,000/23,500
25,000/17,500
25,000/18,000
MANIFOLD PRESSURE (IN. WC)
3.5
10.0
3.5
10.0
MIN. INLET PRESSURE (IN. WC)
5.0
11
5.0
11
ORIFICE (DMS) 0-2,000 FT (0-610 M)*
#34/.111 IN.
#50/.070 IN.
#42/.093 IN.
#53/.059 IN.
*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M
ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS
DATE OF MANUFACTURE / DATE DE FABRICATION
2007
2009
2010
2008
JANV
JAN
FEVR
FEB
MARS
MAR
AVR
APR
MAI
MAY
JUIN
JUN
JUIL
JUL
AOÛT
AUG
SEPT
SEP
OCT
OCT
NOV
NOV
DEC
DEC
90°
    5-5/8”
(143mm)
10”(254mm)
10”(254mm)
8-7/8” (225mm)
Co
mb
ust
ible
 Wa
ll
Mur C
omb
ustib
le
HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU 
GAZ -NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE
MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES.
TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91.
CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION 
ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA) POUR LES MAISON MOBILE 
LE STANDARD DE SÉCURITÉ EST TITLE 24CFR, PART 3280 .  CET APPAREIL DOIT ÊTRE INSTALLER SELON LES SPÉCIFICATIONS 
DU MANUFACTURIER.
CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ 
DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE 
MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES 
TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.
DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.
SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE 
CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.
CONDUIT:  CET  APPAREIL  DOIT  ÊTRE  INSTALLER  SEULEMENT  AVEC  UN  CONDUIT  D’ÉVACUATION 
RECOMMANDÉ PAR LE MANUFACTURIER.  TOUJOURS SE RÉFÉRER AU MANUEL D’INSTALLATION.
EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE 
L’APPAREIL DIMINUE DE QUATRE (4)% POUR CHAQUE 1000 PI (405 M).
CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR.
DANGER:
CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE 
INSTALLÉ À L’ÉCART DES ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. 
SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIÈCE. GARDEZ LA ZONE AUTOUR DU 
FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES 
INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT 
TEMPS. VOIR LES MANUELS D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. 
SEUL LE PANNEAU VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. 
EN AUCUN CAS, L’APPAREIL NE PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE 
REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE  INSTALLATION  INADÉQUATE  DE  MÊME  QU’UN  AJUSTEMENT,  UNE 
MODIFICATION,  UNE  RÉPARATION  OU  UN  ENTRETIEN  INCORRECTS  PEUVENT  CAUSER  DES 
BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. RÉFÉREZ-VOUS AU MANUEL D’ENTRETIEN LIVRÉ AVEC 
CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE 
DE SERVICE OU UN FOURNISSEUR DE GAZ.
SPÉCIFICATIONS
Vision 35 (VIS35)
Vision 25 (VIS25)
GAZ NATUREL
GAZ PROPANE
GAZ NATUREL
GAZ PROPANE
ENTRÉE MAX/MIN BTU/HR 0-4500 pi (0-1370 
M)*
35000/23000 35000/23500 25000/17500
25000/18000
PRESSION À LA SORTIE  (IN. WC/C.E.)
3.5
10.0
3.5
10.0
PRESSION MINIMUM D’ENTRÉE DU GAZ 
(IN. WC/C.E.)
5.0
11
5.0
11
ORIFICE (DMS) 0-4500 pi (0-1370 M)*
#34/.111"
#50/.070"
#42/.093"
#53/.059"
* L’APPAREIL PRÉUSINÉ EST MUNI D’ÉQUIPEMENT POUR 0-2000 PIEDS (0-610 M). AU CANADA 0-4500 PIEDS (0-1370M).
SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES 
NE PAS RETIRER CETTE ÉTIQUETTE        
Fabriqué aux  U.S.A.
IGN
Poêle
Poêle
Stove
Stove
Safety / Listing Label