Hotpoint hvf 344 Benutzerhandbuch

Seite von 16
3
G B
Connecting  the  drain  hose
Connect the drain
hose,  without  bending
it, to a draining duct or
a wall drain situated
between 65 and 100 cm
from  the  floor;
alternatively,  place  it
over the edge of a
basin, sink or tub,
fastening  the  duct
supplied to the tap
(see  figure).  The  free
end of the hose should
not be underwater.
 We advise against the use of hose extensions; in
case of absolute need, the extension must have
the same diameter as the original hose and must
not exceed 150 cm in length.
Electric  connection
Before plugging the appliance into the mains
socket,  make  sure  that:
• the socket is earthed and in compliance with
   the applicable law;
• the socket is able to sustain the appliance's
   maximum power load indicated in the Technical
   details table (on the page 5);
• the supply voltage is included within the values
   indicated on the Technical details table
   (on the page 5);
• the socket is compatible with the washing
   machine's plug. If this is not the case, replace
   the socket or the plug.
Your appliance is now supplied with a 13 amp fused
plug it can be plugged into a 13 amp socket for
immediate  use.  Before  using  the  appliance  please
read  the  instructions  below.
WARNING - THIS APPLIANCE MUST BE EARTHED.
THE FOLLOWING OPERATIONS SHOULD  BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Replacing  the  fuse:
When replacing a faulty fuse, a 13 amp ASTA
approved fuse to BS 1362 should always be used,
and the fuse cover re-fitted. If the fuse cover is
lost, the plug must not be used until a
replacement  is  obtained.
Replacement  fuse  covers:
If a replacement fuse cover is fitted, it must be of
the correct colour as indicated by the coloured
marking or the colour that is embossed in words
on the base of the plug. Replacements can be
obtained  directly  from  your  nearest  Service
Depot.
Removing the plug:
If your appliance has a non-rewireable moulded
plug and you should wish to re-route the mains
cable  through  partitions,  units  etc.,  please  ensure
that  either:
the plug is replaced by a fused 13 ampere re-
wearable plug bearing the BSI mark of approval.
or:
the mains cable is wired directly into a 13 amp
cable outlet, controlled by a switch, (in compliance
with BS 5733) which is accessible without moving
the  appliance.
Disposing of the plug:
Ensure that before disposing of the plug itself,
you make the pins unusable so that it cannot be
accidentally  inserted  into  a  socket.
Instructions for connecting cable to an alternative
plug:
Important: the wires in the mains lead are
coloured in accordance with the following code:
Green  &  Yellow E a r t h
B l u e
N e u t r a l
B r o w n
L i v e
65 - 100 cm