Application Precautions
4
• When the size to be processed by the instruction operand is fixed: 
The number of array elements must be the same as the number of ele-
ments to be processed by the instruction. Otherwise, the CX-Programmer
will output an error when compiling.
• When the size to be processed by the instruction operand is not fixed: 
The number of array elements must be greater than or the same as the
size specified in the other operands.
• If the other operand specifying a size is a constant, the CX-Program-
mer Ver. 5.0 will output an error when compiling.
• If the other operand specifying a size is a variable, the CX-Programmer
Ver. 5.0 will not output an error when compiling, even if the size of the
array variable is not the same as that specified by the other operand
(variable). A warning message, however, will be displayed. In particu-
lar, if the number of array elements is less than the size specified by
the other operand (e.g., the size of the instruction operand is 16, and
the number of elements registered in the actual variable table is 10),
the instruction will execute read/write processing for the area that ex-
ceeds the number of elements. For example, read/write processing will
be executed for the 6 words following those for the number of elements
registered in the actual variable table. If these words are used for other
instructions (including internal variable allocations), unexpected oper-
ation will occur, which may result in serious accidents.
Check that the system will not be adversely affected if the size of the
variable specified in the operand is less than the size in the operand
definition before starting PLC operations. 
!Caution Confirm safety at the destination node before transferring a program to
another node or changing contents of the I/O memory area. Doing either of
these without confirming safety may result in injury.
!Caution Execute online editing only after confirming that no adverse effects will be
caused by extending the cycle time. Otherwise, the input signals may not be
readable.
!Caution Confirm safety sufficiently before monitoring power flow and present value
status in the Ladder Section Window or when monitoring present values in the
Watch Window. If force-set/reset or set/reset operations are inadvertently per-
formed by pressing short-cut keys, the devices connected to Output Units
may malfunction, regardless of the operating mode of the CPU Unit.
4
Application Precautions
Observe the following precautions when using the CX-Programmer.
• User programs cannot be uploaded to the CX-Programmer. 
• Observe the following precautions before starting the CX-Programmer.
• Exit all applications not directly related to the CX-Programmer. Partic-
ularly exit any software such as screen savers, virus checkers, E-mail
or other communications software, and schedulers or other applica-
tions that start up periodically or automatically.
• Disable sharing hard disks, printers, or other devices with other com-