T8775A,C THE DIGITAL ROUND™ NON-PROGRAMMABLE THERMOSTATS
69-1677EF—1    J.S.  Rev. 6-04 
Printed in Hungary
www.honeywell.com/yourhome
Automation and Control Solutions
Honeywell International Inc.
Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North
35 Dynamic Drive
Golden Valley, MN  55422
Scarborough, Ontario
M1V 4Z9
Fig. 10. T8775 Thermostat (features and operation).
SYSTEM Switch
Heat:  The thermostat controls the heating 
system.
Off:
Both heating and cooling systems are off.
Cool: The 
thermostat 
controls the cooling 
system.
FAN Switch
Auto:  The fan only runs with the heating and 
cooling system.
On: 
The fan runs continuously. Use for 
improved air circulation.
CHECKOUT
NOTE:
Temperature setpoint range is 40°F to 90°F 
(4°C to 32°C) in heating and 45°F to 99°F 
(7°C to 37°C) in cooling.
Heating
1. Slide the SYSTEM switch to Heat and the FAN 
switch to Auto (T8775C only).
2. Raise the temperature setpoint several degrees 
above the room temperature.
3. A flame   will appear in the display and the 
heat should turn on.
4. Lower the temperature setpoint below the room 
temperature.
5. The flame   will disappear from the display 
and the heat should turn off.
Cooling (T8775C only)
CAUTION
Low Temperature Hazard.
Operating at too low of an outdoor 
temperature may cause compressor 
damage.
Do not operate cooling if outdoor temperature 
is below 50°F (10°C). Refer to manufacturer’s 
recommendations. 
NOTE:
If a call for cooling is made before the com-
pressor has been off for five minutes, or if a 
power interruption occurs while the com-
pressor is running, the thermostat will go 
into a five-minute delay to protect the com-
pressor. The snowflake 
 will flash during 
this delay.
1. Slide the SYSTEM switch to Cool and the FAN 
switch to Auto.
2. Lower the temperature setpoint several 
degrees below the room temperature. 
3. After approximately five minutes, the thermo-
stat will display a solid snowflake   and the 
cooling should turn on.
4. Raise the temperature setpoint above the room 
temperature.
5. The snowflake   will disappear from the dis-
play and the cooling should turn off. 
Fan
1. Slide the SYSTEM switch to Off and the FAN 
switch to On. The fan should run continuously.
2. Slide the FAN switch to Auto. The fan should 
turn off.
ROOM
SET
DISPLAYS ROOM 
OR SET TEMPERATURE
M19520
SHOWS THAT THE
CURRENT TEMPERATURE
SETPOINT IS DISPLAYED.
(T8775C ONLY)
SELECTS
ON/AUTO
(T8775C ONLY)
SELECTS 
COOL/OFF/HEAT
DISPLAYS AND ADJUSTS 
TEMPERATURE SETPOINT/TURNS
BACKLIGHT ON
SHOWS THAT THE
CURRENT ROOM 
TEMPERATURE IS
DISPLAYED.