Hitachi L100 Benutzerhandbuch

Seite von 192
L100 Inverter
Appendix A
A–7
Single-phase power
An AC power source consisting of Hot and Neutral wires. An Earth 
Ground connection usually accompanies them. In theory, the 
voltage potential on Neutral stays at or near Earth Ground, while 
Hot varies sinusoidally above and below Neutral. This power source 
is named Single Phase to differentiate it from three-phase power 
sources. Some Hitachi inverters can accept single phase input 
power, but they all output three-phase power to the motor. See also 
Three-phase.
Slip
The difference between the theoretical speed of a motor at no load 
(determined by its inverter output waveforms) and the actual speed. 
Some slip is essential in order to develop torque to the load, but too 
much will cause excessive heat in the motor windings and/or cause 
the motor to stall.
Squirrel Cage
A “nick-name” for the appearance of the rotor frame assembly for 
an AC induction motor. 
Stator
The windings in a motor that are stationary and coupled to the 
power input of the motor. See also Rotor.
Tachometer
1. A signal generator usually attached to the motor shaft for the 
purpose of providing feedback to the speed controlling device of the 
motor. 2. A speed-monitoring test meter that may optically sense 
shaft rotation speed and display it on a readout.
Thermal Switch
An electromechanical safety device that opens to stop current flow 
when the temperature at the device reaches a specific temperature 
threshold. Thermal switches are sometimes installed in the motor in 
order to protect the windings from heat damage. The inverter can 
use thermal switch signals to trip (shut down) if the motor 
overheats. See also Trip.
Thermistor
A type of temperature sensor that changes its resistance according 
to its temperature. The sensing range of thermistors and their 
ruggedness make them ideal for motor overheating detection. 
Hitachi inverters have built-in thermistor input circuits, which can 
detect an overheated motor and shut off (trip) the inverter output.
Three-phase power
An AC power source with three Hot connections that have phase 
offsets of 120 degrees is a 3-phase power source. Usually, Neutral 
and Earth Ground wires accompany the three Hot connections. 
Loads may be configured in a delta or Y configuration. A Y-
connected load such as an AC induction motor will be a balanced 
load; the currents in all the Hot connections are the same. There-
fore, the Neutral connection is theoretically zero. This is why 
inverters that generate 3-phase power for motors do not generally 
have a Neutral connection to the motor. However, the Earth Ground 
connection is important for safety reasons, and is provided.