Omron rs6 Benutzerhandbuch
3.
5
U
sing th
e
Memory Functi
on
T
he m
onit
or
aut
omat
ically s
tores
t
he r
esult
up
to
90 s
e
ts
.
It
can al
s
o
c
a
lc
ulat
e an
av
erage reading
bas
ed
on t
he
m
easurem
ent
s
f
rom
t
he last
t
h
ree
readings
ta
k
en w
it
h
in 10
m
inut
es.
I
f
th
ere ar
e only
tw
o
readings
in m
e
m
o
ry
fo
r
th
a
t
period,
t
he av
erage
wil
l
be bas
ed on
tw
o readings
.
If
t
here
is
one reading
in mem
ory f
o
r
that
period,
t
he
av
erage wi
ll be
based
on
one r
eadi
n
g
.
Notes
:
•
If the m
e
mo
ry
is
full
, the
monit
o
r will delete the oldes
t
readings.
•
W
hen
v
iew
ing t
h
e
reading t
a
k
en
w
it
hout
set
ting t
he dat
e
and
ti
m
e
, “-:
--” i
s
display
ed
inst
ead of
t
he dat
e and t
ime
.
T
o
V
iew t
he A
verage
V
a
lu
e
T
o
V
iew
the
Readi
ngs S
tored in
Memory
T
o
D
e
let
e
Al
l the
V
a
lu
es S
tored in Memor
y
Not
e:
Y
ou cannot
p
a
rt
ially delet
e t
he st
ored readings.
4.
1
The Icons and Error
Messag
es
Not
e:
T
he irregular
heart
beat
sy
mbol
(
) and
the
mov
ement
er
ror
sym
bol
(
) may
also be di
s
p
layed wi
th
error mes
sages.
4.
2
T
roubl
eshoot
ing
4.
3
M
ai
nt
enance
T
o
pr
o
tec
t y
our
un
it
fr
o
m
d
ama
ge, p
le
a
s
e
ob
se
rv
e t
he
fo
llo
win
g
:
•
D
o n
ot s
u
b
jec
t t
he m
a
in
un
it a
nd
the c
u
ff
t
o
ex
tr
eme
tem
per
at
ur
es
, hum
id
ity
, mo
is
tur
e
or
di
re
ct
su
nli
gh
t.
•
D
o n
ot d
is
a
s
s
e
mbl
e t
he u
nit
.
•
D
o n
ot s
u
b
jec
t t
he u
nit
to s
tron
g s
hoc
k
s
o
r
v
ibr
at
ion
s (
fo
r
exa
mpl
e,
dr
opp
ing
the
uni
t o
n
the
flo
o
r).
•
D
o n
o
t u
s
e
vo
la
til
e l
iqu
id
s t
o
c
lea
n th
e m
a
in
uni
t.
•
D
o n
o
t w
a
s
h
the
c
u
ff
or i
mme
rs
e i
t i
n
wa
ter
.
•
D
o n
o
t u
s
e
pet
ro
l, t
h
in
ner
s
or
s
im
ila
r so
lv
ent
s
to
c
lea
n th
e c
u
ff
.
•
D
o
no
t c
a
rr
y
ou
t r
epair
s
o
f
any
k
ind
yo
ur
se
lf.
If
a
de
fec
t oc
c
u
rs
,
c
o
n
s
u
lt
y
o
ur OMRON ret
ai
l
outl
et
or
di
s
tr
ibu
tor
as
me
nti
one
d on
the
p
a
c
k
a
g
ing.
•
T
he
uni
t s
hou
ld
be c
le
ane
d wi
th a
so
ft, d
ry
c
lo
th.
•
U
s
e
a
so
ft, mo
is
ten
ed c
loth a
nd
neut
ra
l s
o
a
p
to
c
lea
n th
e c
u
ff
.
•
K
e
ep
the u
n
it
in
it
s
s
tor
ag
e c
a
s
e
wh
en n
ot i
n
us
e.
•
F
ol
d th
e c
u
ff
in
to th
e s
tor
ag
e c
a
s
e
.
Do
not
st
or
e th
e un
it i
n
t
he fo
llowi
ng s
ituat
ion
s:
•
If
the u
n
it
is
we
t.
•
L
o
c
a
tio
ns
ex
pos
ed
to e
x
tr
em
e te
mpe
ratur
es
,
h
u
m
id
ity
, di
re
ct
su
n
lig
h
t,
du
st
o
r co
rro
si
ve
v
apo
ur
s.
•
L
o
c
a
tio
ns
ex
pos
ed
to v
ib
ratio
ns
, s
hoc
k
s
o
r
wh
er
e i
t wil
l
be a
t an
ang
le.
Cali
brat
io
n and
Servi
ce
•
T
he
a
c
c
u
ra
c
y
o
f t
h
is
blo
od
pr
es
s
u
re
mo
nito
r h
a
s
be
en c
a
re
full
y
tes
ted
and
is
de
si
gn
ed fo
r
a l
ong
se
rv
ice
l
if
e
.
•
It
is
gen
er
al
ly
r
e
c
omm
end
ed t
o
ha
ve
the
uni
t
in
s
pec
ted
ev
er
y
two y
e
a
rs
to
ens
ur
e c
o
rr
e
c
t
fu
nct
ion
in
g
an
d ac
c
u
ra
c
y. P
leas
e c
o
n
s
ul
t y
o
u
r
au
thori
s
e
d
O
M
RO
N
deal
er or th
e O
M
R
O
N
Cu
sto
mer
S
e
rv
ic
e at
the
add
re
ss
gi
ve
n o
n
the
p
a
ck
agi
ng
or
att
a
c
h
ed l
it
e
ra
tur
e.
Not
e:
S
ubject
t
o
t
e
chnical modif
ic
at
ion wi
thout
prior not
ic
e.
•
T
hi
s
dev
ic
e f
u
lf
ils
th
e
provis
io
ns
of
E
C
dire
ct
ive
93/
42/
E
E
C
(M
edi
c
a
l Dev
ic
e Direc
ti
ve)
.
•
T
hi
s
blood pres
sure m
o
nit
or
is designed
accord
in
g
to
t
h
e E
u
ropean
S
tandard
EN1060,
N
on-invasive
sphy
gmom
anom
et
ers
P
a
rt
1:
G
e
neral R
equi
re
ment
s
and P
a
rt
3:
S
u
pplement
ary
requirem
ent
s
fo
r elect
rom
echanical
bl
o
od pres
sure
meas
uring s
yst
ems
.
•
T
hi
s
O
M
RO
N produc
t is produce
d
un
der t
h
e st
rict
qual
it
y sy
st
em
of
OMRON HE
A
L
THCA
RE
Co
. Lt
d.,
Jap
a
n.
The Core com
p
onent
f
o
r
O
M
RO
N bl
oo
d
press
ure
m
onit
or
s,
which
is t
he Pres
sure Sensor
, is
produc
ed in
Jap
an.
Made in
China
Pr
es
s the
bu
tton
.
Not
e:
If
t
here ar
e no
meas
urem
ent
s
re
sult
s
s
tored
in t
he
mem
ory
, t
he
s
c
reen
to
t
he right
is
displayed.
1.
Pr
es
s
the
bu
tton
, whi
le
the
av
er
age
va
lu
e is
dis
pl
ay
ed.
T
he Mem
ory num
ber
appears f
o
r
a second
bef
ore t
h
e
pulse rat
e
is
di
s
p
layed.
T
he
new
est
set
is numbered
“1”.
2.
Pr
es
s
the
bu
tton
r
e
pea
tedl
y
to v
iew th
e
re
adi
ngs
s
tor
ed
in
mem
or
y.
W
h
e
n
th
e m
e
m
o
ry
sy
m
bol
(
) app
ea
rs, f
irs
t pre
ss
th
e
butt
on.
Th
en w
h
ile ho
ldi
ng it do
w
n, pre
ss
th
e
S
T
AR
T/ST
OP but
ton si
mul
ta
n
e
o
usl
y for
a
bou
t
2 -
3
se
co
nd
s.
Erro
r Disp
la
y
Cau
se
Re
med
y
Irregular heart
be
at
s
are det
ec
ted.
Remo
v
e
t
he wris
t c
u
ff.
W
a
it
2 -
3 m
inut
es
and t
hen
ta
ke
anot
h
e
r m
easurem
ent
.
Repeat
t
he s
tep
s
in
sect
ion
3.
3.
I
f t
h
is
err
or c
ont
inues
t
o
appear
,
cont
act
your
doc
to
r.
Mo
vemen
t during
me
asurem
ent
.
Caref
ull
y
read and r
epeat
t
he
st
ep
s i
n
sec
tion 3.
3.
Blink
T
he bat
te
ri
e
s
ar
e
low
.
Y
ou s
hould replace t
hem
wi
th
new ones ahead
of
t
ime.
Ref
e
r t
o
s
e
ct
ion
2.
1.
Li
t
T
he bat
te
ri
e
s
ar
e
exhaus
ted.
Y
ou s
hould replace t
hem
wi
th
new ones at
once.
Ref
e
r t
o
s
e
ct
ion
2.
1.
Wri
s
t cu
ff
n
o
t
applied c
o
rrect
ly
.
Apply t
he
wris
t cuf
f
c
o
rrect
ly
.
Ref
e
r t
o
s
e
ct
ion
3.
1.
Mo
vemen
t during
me
asurem
ent
.
Repeat
M
easurem
ent
while
rem
ai
ning st
ill and
ref
raining
fr
om t
a
lking during
the
meas
urem
ent
.
Ref
e
r t
o
s
e
ct
ion
3.
3.
Wri
s
t cu
ff
n
o
t
applied c
o
rrect
ly
, or
mo
vemen
t during
me
asurem
ent
.
Apply t
he
wris
t cuf
f
c
o
rrect
ly
and r
epeat
mea
surem
ent
while rem
aining st
ill
and
ref
raini
ng
f
rom
ta
k
ing dur
ing
the me
asurem
ent
.
Ref
e
r t
o
s
e
ct
ion
3.
1 and
3.
3.
Ar
m posit
ion
change
d during
me
asurem
ent
.
Rema
in
stil
l unt
il
the
meas
urem
ent
i
s
c
o
mplet
e.
Ref
e
r t
o
s
e
ct
ion
3.
3.
Devic
e err
or
.
Cont
act
your
O
M
R
O
N
ret
ail
out
let
or
dist
ribut
or
.
Alt
ernat
ing
date/
ti
m
e
display
F
irs
t
S
econd
4.
T
roublesh
ooti
ng an
d Mai
ntenance
Pro
b
lem
Cau
se
Remed
y
T
h
e
reading
is
ext
remely
low
(or high).
The wrist cuf
f is n
o
t
at hear
t
le
v
el.
M
easur
e
while i
n
t
h
e
c
o
rrec
t post
u
re.
R
e
fe
r t
o
sec
tion 3.
2.
T
he c
u
ff
is
not
wrapp
ed sn
ugl
y
around
t
he wris
t.
W
rap t
he
cu
ff
corr
ect
ly
.
R
e
fe
r t
o
sec
tion 3.
1.
T
he ar
ms
and
sho
ul
der
s a
re
tense.
R
e
la
x
and t
ry t
a
king t
h
e
m
easur
ement
again.
R
e
fe
r t
o
sec
tion 3.
3.
M
o
vem
ent
or
talking dur
ing
m
easurem
ent
.
R
e
main st
ill
and do not
ta
lk during
M
easur
ement
.
R
e
fe
r t
o
sec
tion 3.
3.
W
ris
t c
u
ff p
re
s
s
u
re
does not
rise.
A
ir
is
le
aking f
rom
the wr
is
t
cuf
f.
C
onsult
your O
M
RO
N
re
ta
il
o
u
tl
et
or dist
ri
but
or
.
W
ris
t c
u
ff
d
e
fl
a
te
s
too soon.
T
h
e
w
ri
s
t c
u
ff is
loose.
A
p
ply t
he cuf
f
c
o
rrect
ly so
that
it
is f
irm
ly
wr
apped
a
round
the wrist
. Ref
er t
o
s
e
ct
io
n 3.
1.
T
h
e
blood
pressu
re is
dif
ferent
each t
im
e
. T
he reading i
s
ext
remely
low (
o
r high)
.
B
lood pr
essur
e readings
c
onst
ant
ly
var
y w
it
h
t
ime
o
f day and
how relaxed
y
ou
ar
e.
T
a
ke sev
eral
d
eep
brea
th
s and t
ry
t
o
re
main relaxed bef
or
e
ta
king a
m
e
asur
ement
.
T
h
e
unit
loses
power during
meas
uremen
t.
T
he ba
tt
eries a
re
exh
aust
ed
.
R
epl
a
c
e t
h
e bat
teries wit
h
n
ew ones
.
R
e
fe
r t
o
sec
tion 2.
1.
Not
hing happens
when y
ou pr
ess
the but
tons.
T
he bat
teries
have
been insert
ed
incorr
e
ctl
y.
In
ser
t t
he bat
teries wit
h
the correc
t (+/
-)
polarit
y.
R
e
fe
r t
o
sec
tion 2.
1.
O
ther problem
s.
•
P
res
s t
he ST
AR
T
/S
T
O
P
but
to
n
and repeat
meas
ureme
nt
.
•
If
t
he p
roblem
cont
in
u
e
s,
t
ry r
e
placing t
he
bat
te
ries wit
h new ones.
If
t
h
is st
ill does not
solve t
he problem
, cont
act
you
r O
M
RO
N ret
ail out
let
or dis
tribut
or
.
P
roduct
De
script
ion
W
rist
B
loo
d P
ressur
e M
onit
or
M
odel
O
M
RO
N
RS
6 (H
EM-
6221-E)
Display
LCD Digit
al Display
M
easurem
ent
M
e
th
od
O
s
c
illom
et
ric
me
th
od
M
easurem
ent
Range
P
ressu
re:
0 t
o
2
99 m
m
Hg
P
u
ls
e:
40
to
180
beat
s/
min.
A
ccur
acy
P
ressu
re:
±
3
mm
Hg
P
u
ls
e:
±
5
%
of
dis
pl
ay
rea
di
ng
In
fl
at
io
n
A
ut
om
at
ic inf
lat
io
n
by pum
p
Def
lat
ion
A
u
to
m
a
tic rapid def
lat
ion
M
e
mor
y
90 Meas
ureme
nt
s
P
o
wer Sourc
e
2
x 1.
5V
(LR
03,
AA
A al
k
a
line bat
teries)
B
a
tt
ery
Lif
e
A
pprox.
300
me
asurem
ent
s
wit
h new
alkaline bat
teries at
a room
t
e
m
p
erat
u
re of
23°
C
A
ppli
ed
Par
t
=
T
y
pe B
P
rot
ec
ti
on Against
E
le
c
tr
ic
S
h
o
c
k
In
te
rn
al
ly powere
d
M
E
equi
p
m
ent
O
perat
ing t
empe
rat
u
re
/
Hum
idit
y
+10 t
o
+40
°C
/
M
a
ximum
: 30 t
o
85%
R
H
S
torage t
e
m
perat
ure/
Hum
idit
y/Air press
ure
-20
to
+60
°C / M
a
xim
u
m: 10
to
95%
RH /
700 t
o
1060hP
a
Cons
ole
W
eight
A
pproxim
at
ely 85
g wit
ho
ut
bat
teries
O
u
te
r D
im
ensions
A
pproxim
at
ely
87 (
w
) m
m
x
64 (
h
) m
m
x
14
(d)
mm
(w
it
hout
t
h
e wr
is
t
cuf
f)
M
easurable
ci
rc
u
m
fe
re
n
c
e
A
pproxim
at
ely 13.
5 t
o
21.
5
c
m
Cuf
f Mat
erial
Ny
lon and polyest
er
P
a
ckage
Cont
ent
M
a
in unit
,
st
or
age c
a
se,
bat
te
ry
s
e
t,
inst
ruct
ion m
a
nual,
guarant
ee c
a
rd,
blood
pres
sure p
a
ss
5.
T
echni
cal
Dat
a
Im
p
o
rt
an
t i
n
fo
rmat
io
n
reg
ard
in
g
El
ectro
M
a
g
n
eti
c
Comp
a
ti
b
ili
ty
(
E
M
C
)
W
it
h
t
he increas
ed
num
ber of
elect
ronic devices suc
h
as
P
C
’s
and
m
obi
le (cellular) t
e
lephones
, medica
l devices
in use may be
sus
cept
ib
le
t
o
elect
roma
gnet
ic int
e
rf
erenc
e
fr
om ot
her
dev
ices.
E
lec
tr
om
agnet
ic
int
erf
e
rence
may
res
ul
t in
incorrec
t
operat
ion of
the m
edical dev
ic
e and
cr
eat
e
a pot
ent
ially
unsaf
e s
it
uat
io
n
.
M
edi
c
a
l dev
ic
es
should als
o not
int
erf
e
re
wit
h ot
her
devices.
In
orde
r t
o
r
egul
at
e
th
e
requirem
ent
s
f
o
r E
M
C
(E
le
c
tro
M
agnet
ic
Com
p
a
tibilit
y)
wit
h the aim to prev
ent
u
n
saf
e
product situat
ions, the
E
N
60601-1-2:
2007 s
tandar
d has b
een implem
ent
ed.
T
h
is st
andard
def
in
es
th
e l
e
v
e
ls
of
i
m
munit
y t
o
el
e
c
tr
omagnet
ic
int
erf
erences
as
well as
m
a
ximum
lev
el
s
of
elec
tr
om
agnet
ic
em
issions
fo
r m
e
dical
devic
e
s.
This
m
e
dic
al dev
ic
e manufac
tured by
OM
RON
HE
A
L
THCA
RE
conf
orm
s t
o
t
h
is E
N
60601-1-
2:
2007 s
tandar
d f
o
r bot
h imm
unit
y
and
em
is
sions.
Nev
ert
heles
s,
spec
ia
l precau
ti
ons need
to
be
obs
erved:
•
D
o
no
t use mobile
(c
ell
ular)
t
e
lephones and
ot
her devices
, which
generat
e s
trong
elect
rical or
elect
rom
agnet
ic
fi
elds,
near t
he
medica
l
device.
T
h
is
may
res
ult
i
n
incorr
ect
operat
ion of
t
h
e
uni
t
and
c
reat
e
a pot
ent
iall
y
uns
af
e sit
uat
ion.
Recom
me
ndat
ion i
s
t
o
keep a
m
ini
m
u
m dist
ance of
7
m
. V
e
rif
y
co
rrect
oper
at
ion of
t
he
device
in c
a
se t
h
e
di
s
tanc
e is
shor
te
r.
F
u
rt
her doc
ument
at
ion
in ac
cordanc
e wit
h E
N
60601-1-
2:
2007
is
av
ailable
at
O
M
RON
HE
A
L
T
H
C
A
RE
E
UROP
E
at the addr
es
s
m
ent
ioned
in t
h
is
inst
ruc
tion m
anual.
Doc
ument
at
ion is
als
o
ava
ilable at
www
.o
mr
on-healt
hc
are.
com.
Co
rrect Di
sp
o
sal
o
f
T
h
is Pro
d
u
ct
(W
aste
El
ectri
cal
&
El
ectro
n
ic
Eq
u
ip
m
en
t)
T
h
is
m
a
rk
in
g shown
on t
h
e product
or
it
s
lit
erat
ure,
indicat
es
that
it
s
hould not
be
dispos
ed of
, wit
h ot
her
househ
ol
d
was
tes
at
t
he
end of
it
s
work
ing
lif
e.
T
o
prev
ent
poss
ib
le harm
t
o
t
h
e
e
n
vironme
nt
or
h
u
man healt
h f
rom
unco
nt
rolled
wast
e dispos
al,
pl
ea
se s
e
p
a
rat
e t
h
is p
roduct
f
rom
ot
her t
y
pes
of
was
te
s
and
recy
cle it
re
sponsibly
to
prom
ot
e
the
sus
tainable reuse of
ma
te
rial
re
sourc
es.
Hous
ehold use
rs
should c
ont
ac
t
eit
her
th
e ret
ailer whe
re t
hey
purc
hased t
h
is produc
t,
or t
h
ei
r
local governm
ent
of
fi
ce,
f
o
r
det
ails
of
wher
e and
how t
h
ey
can
ret
urn t
h
is
it
em
fo
r env
ir
onment
all
y
s
a
fe
rec
ycling.
B
u
siness user
s
s
hould
c
o
nt
ac
t t
h
eir supplier and
c
h
eck t
h
e t
e
rm
s
and con
di
tions of
t
he purch
ase cont
ract
. T
h
is produc
t shou
ld
not
be
m
ix
ed
wit
h
ot
her com
merc
ial wast
es f
o
r dispos
al
.
M
a
n
u
fact
u
rer
OM
RO
N HEAL
T
HCARE Co
., L
td
.
53, K
uno
ts
u
bo, T
e
rado
-ch
o,
M
u
ko
,
K
y
o
to,
6
1
7
-0
00
2 J
A
P
A
N
E
U
-rep
res
en
tati
ve
OM
RO
N HEAL
T
HCARE EUROPE B.V
.
S
c
or
pi
u
s
33
, 21
32
LR
H
o
of
d
d
o
rp
T
H
E NET
HERL
ANDS
www
.o
m
ron
-he
alth
car
e.co
m
Pr
oduc
ti
on Fa
c
il
it
y
OM
RO
N (
DAL
IAN)
CO.,
L
T
D.
Da
lia
n
, CHINA
Su
bs
id
ia
ry
OM
RO
N HEAL
T
HCARE UK L
T
D.
O
p
al
D
ri
v
e,
Fo
x
Mi
ln
e,
M
ilt
o
n
K
e
y
n
es
, MK
15
0D
G
U.K.
OM
RO
N M
E
DI
Z
INT
ECHNIK
HANDEL
SG
ESEL
L
S
CHAF
T
mb
H
John
-D
e
e
re
-S
tr
. 81a
681
63
M
a
n
nhe
im
, G
E
R
M
A
N
Y
www
.o
m
ron
-m
edizin
tech
nik.d
e
OM
RO
N SANT
É
F
RANCE SAS
14,
rue
de
Lisb
on
ne,
935
61
Rosn
y-so
us-
B
o
is
Ce
d
e
x, F
R
ANCE