Dacor ER36D-C Benutzerhandbuch

Seite von 24
 WARNING
IMPORTANT: Observe all governing codes and ordinances 
during planning and installation. Contact your local building 
department for further information.
Electrical Requirements - U.S.A.
IMPORTANT: The information below does not apply to units 
equipped for use in Canada.
It is the owner’s responsibility to ensure that the electrical 
connection of this appliance is performed by a licensed  
electrician. The electrical installation, including minimum supply 
wire size and grounding, must be in accordance with the National 
Electric code ANSI/NFPA 70-1993* (or latest revision) and local 
codes and ordinances. The standard is available from:
National Fire Protection Association 
1 Batterymarch Park 
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and amperage must be 
supplied to the appliance from a separate, grounded, circuit 
that is protected by a properly sized circuit breaker or time 
delay fuse. Refer to the data on the range rating label.
NOMINAL ELECTRIC CIRCUIT REQUIREMENTS - U.S.A.
Range 
Model
Circuit Required
Total Connected 
Load
ER36D 240 Vac*, 60 Hz, 30 Amp. (Min.)  
40 Amp. (Recommended) 
6.5 kW (28 Amp.)
ER48D
240 Vac*, 60 Hz, 50 Amp.
10.0 kW (42 Amp.)
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
The ratings above are for reference only. Refer to the range 
data label for exact specifications (see page 3 for location).
Consult local building codes for the type and minimum wire 
gauge to use for the power requirements on the rating label.
Suggested wiring color code: Black, white, red and green.
The wiring needs to be long enough to allow the range 
to be pulled out from the wall for service while remaining 
connected. See page 10 for further details.
The wiring to the range must:
Have a minimum rating of 250 Volts @ 30 Amps for 
model ER36D, 250 Volts @ 50 amps for model ER48D.
Include a strain relief
Be terminated by tinned leads, closed loop terminals or 
open ended spade lugs with upturned ends
Where local code permits, a three (3) or four (4) wire 
appliance cord may be used. The appliance cord must: 
Be UL listed type SRD or SRDT 
Be equipped with a NEMA 14-50P 4 wire plug or, where 
local code permits, a NEMA 10-50P 3 wire plug.
Prior to range installation, have a licensed electrician install a 
conduit junction box or electrical receptacle according to the 
type of wiring used.


Electrical Requirements - Canada
It is the owner’s responsibility to ensure that the required 4 wire 
electrical outlet is installed by a licensed electrician as specified 
below prior to range installation. The electrical outlet installation, 
including minimum supply wire size and grounding, must be in 
accordance with all governing codes and ordinances.
The correct voltage, frequency and amperage must be 
supplied to the appliance from a separate, grounded, circuit 
that is protected by a properly sized circuit breaker or time 
delay fuse. Refer to the data on the range rating label.
NOMINAL ELECTRIC CIRCUIT REQUIREMENTS - CANADA
Range 
Model
Circuit Required
Total Connected 
Load
ER36D 240 Vac*, 60 Hz, 30 Amp. (Min.)  
40 Amp. (Recommended)
6.5 kW (28 Amp.)
ER48D
240 Vac*, 60 Hz, 50 Amp.
10.0 kW (42 Amp.)
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
The ratings above are for reference only. Refer to the range 
data label for exact specifications (see page 3 for location).
Ranges equipped for use in 
Canada come pre-wired with a  
4 Wire appliance cord and 
NEMA 14-50P plug. 
Do not modify the factory wiring. 
The plug is designed to insert 
directly into a NEMA 14-50R 
electrical receptacle installed by 
a licensed electrician according 
to the above specifications.
Gas Supply Requirements
Check your local building codes for the proper method of 
installation. In the absence of local codes, this appliance 
should be installed in accordance with the National Fuel Gas 
Code ANSI Z223.1. 
Be certain that the appliance being installed is correct for 
the gas service provided (natural gas or LP gas). Also, if 
operating the range at an altitude above 4000 feet. (1219 m) 
make sure it is equipped for high altitude operation. Refer to 
the range data plate and the table on page 3 to determine the 
correct model. 
See the table below for gas supply pressure requirements. 
The regulator inlet accommodates a 3/4” gas line. The range 
ships with a 1/2” to 3/4” adapter connected to the regulator.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Minimum 
Manifold Pressure
Minimum Gas 
Supply Pressure**
Natural Gas
5” Water Column
6” Water Column
Liquid Propane (LP) 10” Water Column
11” Water Column
* The gas supply pressure for testing the regulator setting shall be 
at least 1 inch water column (249Pa) above the specified manifold 
pressure
** Maximum gas supply pressure for all models: 1/2 p.s.i. 
The ratings above are for reference only. Refer to the range 
data label for exact specifications (see page 3 for location).

Planning the Installation
NEMA 14-50P Plug
NEMA 10-50P Plug
NEMA 14-50R Receptacle