Gas Supply Connection
 WARNING
Make sure the gas supply valve is off and that the power 
to the range is turned off at the circuit breaker or fuse box 
prior to connecting the gas line.
Do not apply excessive pressure when tightening gas 
connections and fittings.
Do not use Teflon tape or plumber’s putty on gas flex line 
connections.
For LP installations, the LP gas tank must have its own 
high pressure regulator. This is in addition to the pressure 
regulator provided with the range.
The maximum gas supply pressure to the regulator must 
never exceed 1/2 pound per square inch (psi) or 3.5kPa.
The range and shut-off valve must be disconnected 
from the gas supply piping during any pressure testing 
exceeding 1/2 psi (3.5 kPa).
The range must be isolated from the gas supply piping by 
closing the shut-off valve during any pressure testing at or 
below 1/2 psi (3.5 kPa).
Check all gas lines for leaks as instructed to avoid a fire or 
explosion hazard. Do not use a flame to check for leaks.
NOTE: The gas pressure regulator is pre-set at the factory for the 
type of gas intended for use with the appliance. To verify that the 
appliance is compatible with the type of gas available, check the 
range data plate (see page 3 for location). Ranges intended for 
use with LP gases will have “LP” as a part of the model number. 
Consult your dealer if the range is not compatible with the type of 
gas supplied.
Before sliding the range into the cabinet:
Make sure the gas supply valve is in the off position and that 
power to the range is off.
Connect a flexible gas supply line to the gas shut-off valve 
previously installed on the stub out. The gas line needs to be 
long enough to allow the range to be pulled out for service. 
Remove the gas regulator access cover.
Slide the end of the gas line under the back cover into the 
regulator compartment from the bottom. 
Connect the gas line to the regulator.
Turn all cooktop control valves to the “OFF” position. Turn on 
the gas supply.
Check all lines 
and connections 
for leaks using a 
soap and water 
solution. 
After verifying 
that there are no 
gas leaks, turn 
off the gas supply 
valve connected 
to the range 
to the “OFF” 
position.
Replace the 
regulator access 
cover.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Loop and 
Spade Terminal 
Connections
Bare Wire 
Connections
10-50P Plug
L1
L2
Neutral
3 Wire Appliance 
Cord Connection - 
Where Local Code 
Permits
Strain Relief
White Wire
L1 Wire
Neutral Terminal
L1 Terminal
L2 Terminal
L2 Wire
Jumper Link
Back Cover
Regulator 
Connection
Gas Line
Installation Instructions