Outback Power Systems vfx 3232m Benutzerhandbuch

Seite von 65
Installation & Programming Manual
                              
FX & VFX Series Inverter/Charger System                     
Copyright 2003  
  OutBack Power Systems, Inc. 
 
 
    
900-0027-1
                                                                19009 62
nd
 Ave NE, Arlington   WA 98223 USA                     
Page 46                                         
Rev 7.2
       08/26/05                                                                    Tel 360 435 6030    Fax 360 435 6019  
MATE SCREENS 
ERROR MENU 
The ERROR section allows the user to check the cause of an error condition.  When an error has occurred, the red error LED indicator 
in the FX’s wiring compartment will be illuminated (not to be confused with a blinking “ERROR” LED that indicates a WARNING). If an 
error occurs, the FX will cease operation and the MATE will display an error screen.  Pressing <VIEW ERROR> from this screen brings 
the user to the 1
st
 screen of a list of error causes that will be available by pressing the DOWN button.  The presence of the word “YES” 
to the right of the appropriate cause indicates that this error has occurred.  It is possible for multiple errors to occur simultaneously.  
Check every error condition to make sure.  An error can be cleared by pressing the <INV> button on the MATE and then turning the FX 
<OFF>
 and then <ON>.  The inverter automatically resets from over-temperature and low or high battery voltage conditions. 
MAIN----------------
6:54:42P
SUM STATUS SETUP ADV
STATUS--------------
choose product:
FX
MX
STATUS/FX/PAGE1-----
choose category:
MODES METER BATT PG2
STATUS/FX/PAGE2-----
choose category:
PG1 ERROR
WARN
PG3
STATUS/FX/ERROR—-P00
low ac output
No
voltage
DOWN
STATUS PORT
STATUS/FX/ERROR—-P00
stacking
No
error detected
DOWN
UP
TOP
PORT
STATUS/FX/ERROR—-P00
inverter
No
overtemp
DOWN
UP
TOP
PORT
STATUS/FX/ERROR—-P00
low battery
No
voltage
DOWN
UP
TOP
PORT
STATUS/FX/ERROR—-P00
phase loss
No
error
DOWN
UP
TOP
PORT
STATUS/FX/ERROR—-P00
high battery
No
voltage
DOWN
UP
TOP
PORT
STATUS/FX/ERROR—-P00
ac output
No
shorted
DOWN
UP
TOP
PORT
STATUS/FX/ERROR—-P00
ac output
No
backfeed
DOWN
UP
TOP
PORT
STATUS/FX/ERROR—-P00
end of error menu
UP
TOP STATUS
The MAIN screen is where the menu system starts.  The four words in the bottom line of the 
display correspond to the four buttons located below the display. The word in BOLD on the bottom 
line indicates the selection used to advance the display to the next screen.  Pressing the left two 
buttons simultaneously from anywhere in the menu will return you to this screen. 
Allows selection of the product type: 
<FX>
      
FX inverter/charger system 
MX 
   
MX60 PV MPPT charge controller 
MODES 
Status and allows adjustment of Inverter, AC input, Charger, Aux, and EQ 
METER 
Provides the AC voltages and currents of the FX 
BATT       
Provides the battery voltage and charger set points and timers 
<PG2>
     
Displays additional sections – ERRORS, WARNINGS and PG3 
PG1   
Returns to page 1 of the STATUS section 
<ERROR>
 
Displays the different causes for errors and qualifies each cause with a Yes or No 
WARN  
Displays the different causes for warnings and qualifies each with a Yes or No 
PG3   
Displays additional sections – reason for last DISCONNECT and SELL  
LOW AC OUTPUT VOLTAGE
 indicates that the inverter was not able to maintain adequate AC 
output voltage (105 VAC or above) to power the loads connected. This is typically caused by the 
load demanding more power than the inverter is able to deliver.  
STACKING ERROR DETECTED
 indicates that a problem has occurred with the communication 
cabling between stacked FX’s, or if the FX’s are stacked incorrectly.  Check the stacking 
programming.  If this condition persists contact your dealer for servicing instructions.   
INVERTER OVERTEMP
 indicates that the FX reached its maximum allowed operating temp. This 
can be caused by powering large AC loads or charging for too long.  It can also be caused by 
restricting the amount of air which is able to flow around the casting or operation in high temp 
environments.  The FX will automatically reset and resume operation once it cools down.   
LOW BATTERY VOLTAGE
 indicates that the battery voltage dropped below the LOW BATTERY 
CUT-OUT VOLTAGE set point (default of 10.5 volts for a 12 volt FX) for 5 minutes. The inverter 
will restart once the battery voltage exceeds the LOW BATTERY CUT-IN VOLTAGE set point 
(default of 12.5 volts for a 12 volt FX) for 10 minutes.   
PHASE LOSS ERROR
 is not operational at this time.  If a ‘Yes’ accompanies this Error, please 
disregard and look for other error causes.   
 
HIGH BATTERY VOLTAGE
 indicates that the battery voltage rose above the high battery voltage 
level (default of 20 volts for a 12 volt FX) for 10 seconds. The inverter will restart once the battery 
voltage drops below the high battery voltage (default of 20 volts for a 12 volt FX) for 1 second. 
   
AC OUTPUT SHORTED
 indicates that the inverter immediately reached its maximum current and 
shut down.  This is usually caused by a short circuit condition (hence the AC OUTPUT SHORTED 
label) but can also be caused by attempting to operate a load which far exceeds the inverter 
output capability.   
AC OUTPUT BACKFEED
 indicates that another AC source of power was connected to the AC 
output of the FX. Usually this is an installation issue.  It often occurs when there is an X-240 
transformer in the system that hasn’t been installed properly.  Also, check that there are no 
connections between the AC input and AC output circuitry. 
Selecting TOP returns the user to the top of the STATUS/FX/ERROR menu section.  Selecting 
STATUS returns to the first page of the STATUS screen.