MATE SCREENS    
SELL MENU 
The SELL section of the STATUS menu has only one screen.  This screen gives a number that refers to a reason the FX would stop 
selling.  OutBack Power Systems technicians use this number to quickly understand what the FX thinks is happening.  The system user 
should not be concerned about this number unless they are experiencing many unknown grid disconnects and they need 
troubleshooting help.  This screen is only operational with “Grid-Tie” FX’s.
MAIN----------------
6:54:42P
SUM STATUS SETUP ADV
STATUS--------------
choose product:
FX
MX
STATUS/FX/PAGE1-----
choose category:
MODES METER BATT PG2
STATUS/FX/PAGE2-----
choose category:
PG1 ERROR
WARN
PG3
STATUS/FX/PAGE3-----
choose category:
PG2 DISCON SELL MAIN
STATUS/FX/SELL---P00
stop sell
14
reason
STATUS
PORT
The MAIN screen is where the menu system starts.  The four words in the bottom line of the display 
correspond to the four buttons located below the display. The word in BOLD on the bottom line 
indicates the selection used to advance the display to the next screen.  Pressing the left two buttons 
simultaneously from anywhere in the menu will return you to this screen. 
Allows selection of the product type: 
<FX>
 
    
FX inverter/charger system 
MX 
   
MX60 PV MPPT charge controller 
 
MODES   
Status and allows adjustment of Inverter, AC input, Charger, Aux, and EQ 
METER   
Provides the AC voltages and currents of the FX 
BATT        
Provides the battery voltage and charger set points and timers 
<PG2>  
      
Displays additional sections – ERRORS, WARNINGS and PG3 
PG1 
 
Returns to page 1 of the STATUS section 
ERROR   
Displays the different causes for errors and qualifies each cause with a Yes or No 
WARN   
Displays the different causes for warnings and qualifies each with a Yes or No 
<PG3>
   
Displays additional sections – reason for last DISCONNECT and SELL  
PG2   
    
Displays additional sections – ERRORS, WARNINGS and PG3 
DISCON  
Displays the reason that the FX last disconnected from the AC source 
<SELL>
   
Displays the code related to the reason for the last disconnection while selling 
MAIN 
 
Returns the user to the MAIN menu 
 
The STOP SELL REASON displays a numerical value that indicates a reason that the FX stopped 
selling to the utility grid.  It could indicate that the utility grid’s voltage or frequency is out of the 
acceptable ranges or that the utility grid failed altogether.  This screen is used for troubleshooting by 
OutBack Power Systems technicians.  Selecting STATUS returns the user to the beginning of the 
STATUS menu.  Selecting PORT selects the next FX on the HUB.