MATE SCREENS 
Advanced Screens 
The ADVANCED menu section allows adjustment of all the settings involved with the operation of the FX.  Changes made to these 
settings are stored internally in non-volatile memory inside of the FX – the settings are not lost when the MATE is removed or battery 
power is disconnected.   
Some settings appear both in the SETUP and in the ADV menus.  Changes made to these settings in one area will cause the same 
changes to occur in the other area.  The settings are provided in both menus to make it more convenient for the FX programmer by 
giving access to all of the settings in the advanced menu.   
Access to the settings in the advanced menu is restricted through the use of a password.  This password is required to view and adjust 
the settings.  Once the password has been entered, all ADVANCED categories can be adjusted without having to re-enter the 
password.  If the advanced menu is exited and re-entered, the password must be re-entered, however.  Use of the “Hot” keys AC IN 
and INV is allowed from the advanced menu and selecting OK from these screens will return you to the same point in the advanced 
menu.  
The password for the FX is currently fixed to the same value for all of the FX’s. 
 
PASSWORD CODE:
  
1 4 1 
 
 
MAIN----------------
6:54:42P
SUM STATUS SETUP ADV
ADV/SETTINGS/WARNING
changes made could
adversely effect
system performance
ADV/PASSWORD--------
enter the password:
132
ENTER INC
DEC
EXIT
ADV-----------------
choose product:
FX
MX
MATE
MAIN
ADV/FX/PAGE1--------
choose category:
ADV
INV
CHGR
PG2
ADV/FX/PAGE2--------
choose category:
PG1
GRID
GEN
PG3
ADV/FX/PAGE3--------
choose category:
PG2
AUX
STACK
PG4
ADV/FX/PAGE3--------
choose category:
PG3
SELL
CAL
MAIN
The MAIN screen is where the menu system starts.  The four words in the bottom line of the display 
correspond to the four buttons located below the display. The word in BOLD on the bottom line 
indicates the selection used to advance the display to the next screen.  Pressing the left two buttons 
simultaneously from anywhere in the menu will return you to this screen. 
 
Selecting <ADV> brings up a warning message.  Please read the message.  Pressing any of the four 
keys below the display advances the display to the password screen.   
 
 
Entering the correct password
 number is done by pressing the <INC> key to increase the number 
or the <DEC> key to decrease the number.   Once the number shown matches the password code 
(141)
, press the key below the word <ENTER>.  To leave the advanced menu area without making 
any changes, press EXIT.   
 
Following the password screen is a screen that allows selection of the OutBack product type.  
Selecting <FX> allows adjustment of the FX’s advanced programming.  Selecting MX will allow 
access to the advanced sections of any MX-60’s connected to the system (through a HUB).  Selecting 
MATE will allow access to the MATE’s advanced screens.  Selecting MAIN returns the user to the 
MAIN menu.  
 
There are eight categories of settings in the FX: 
INV
 
     Allows adjustment of the INVERTER settings and operation 
CHGR
       Allows adjustment of the CHARGER settings and operation 
GRID
           Allows adjustment of the AC input settings and operation if the FX’s input is set to GRID 
in the SETUP/FX/INPUT “ac transfer control” screen (see previous page) 
GEN
 
Allows adjustment of the AC input settings and operation if the FX’s input is set to GEN in 
the SETUP/FX/INPUT “ac transfer control” screen (see previous page) 
AUX 
 
     Allows adjustment of the AUXILIARY output settings and operation 
STACK 
     Allows adjustment of the master/slave settings for multi-FX systems  
SELL
 
     Allows adjustment of the Grid-Tie settings and operation 
CAL
 
     Allows adjustment of the voltage calibration measurements to improve operation 
Selecting ADV will send the user back one screen to the “choose product” screen in the advanced 
menu.  PG2 will advance the user to page 2 of the advanced menu.  PG3 will advance the user to 
page 3 of the advanced menu.  PG4 will advance the user to page 4 of the advanced menu.  
Selecting MAIN will return the user to the MAIN screen.