Crestron qm-rmcrx Benutzerhandbuch

Seite von 64
QuickMedia™ Receiver/Processor                             Crestron QM-RMCRX 
5.  While powering up the QM-RMCRX, press and hold ATL and K on 
the keyboard until the following text (or similar) appears in Viewport. 
System Monitor [v1.001 (0001)] 
12-19-01 16:25:23 32MB RAM, 4MB FLASH 
CS> 
NOTE:  After this, you can increase the baud rate to 115200 (for faster 
communication) by pressing F8 on the keyboard and then selecting 115200 from 
the “Set Baud Rate” window. 
6.  At the Viewport prompt, type: erase and press Enter. The following 
text appears in Viewport. 
CS>erase 
->25%->50%->75%->100% 
Done 
CS> 
7.  From Viewport, select File Transfer | Update Control System, or 
press Alt+U, or from Viewport, select: 
       File Transfer | General file transfer | Xmodem 1K upload.  
8.  Find and select the QM-RMCRX CUZ file and click Open
9. 
Once “Completed Successfully” appears in Viewport, type quit at the 
Viewport prompt and press Enter.
 
Battery Replacement 
A Lithium battery is used to power the system clock within the QM-RMCRX. 
Under normal conditions, it lasts for approximately 10 years. In the event that 
the clock fails, only an authorized technician should replace it. Refer to the 
following caution statement.  
CAUTION:  Danger of explosion if battery is incorrectly replaced.  
Replace only with the same or equivalent type recommended by the 
manufacturer. Dispose of used batteries according to the manufacturer's 
instructions.  
Passthrough Mode 
Passthrough mode enables Viewport access to any serially controlled device that 
is connected through a Crestron control processor, on the Cresnet network or the 
Ethernet. That is, it allows direct communication between the PC and a network 
device (effectively "passing through" the QM-RMCRX). While passthrough 
mode is running, the program currently in memory is suspended and will not 
execute. When passthrough mode is exited, the program resumes operation. 
Entering passthrough mode for COM port B reinitializes it, which clears the data 
for that port.  
To establish communication, click Functions | Enter Passthrough Mode. Then 
select the connection type that exists between the QM-RMCRX and the device. 
The choices are Slot (for devices connected to the control system via one of the 
card slots on the back panel), Cresnet, or Ethernet. If the connection is through a 
34 
 QuickMedia™ Receiver/Processor: QM-RMCRX 
Operations Guide - DOC. 6236A