Crestron qm-rmcrx Benutzerhandbuch

Seite von 64
QuickMedia™ Receiver/Processor                             Crestron QM-RMCRX 
(For further information on this procedure, refer to the VT Pro-e online help 
file.) 
Viewport 
To transfer the Web pages to the QM-RMCRX, use the File Transfer | Send 
Web Pages
 command. 
The options are to send an entire project, only files that have changed, or a 
single HTML file. With the “Transfer Entire Project” option, click OK when 
reminded to select a default page, and then browse to the appropriate VT Pro-e 
.web project folder. Select the file that was designated as the “first” page of the 
project. This will be the default Web page that is displayed whenever the IP 
address of the control system is accessed by a Web browser. Click Open, and 
then OK to begin the transfer. 
If any files in the VT Pro-e project change, the changed files can be transferred 
to the QM-RMCRX without resending the entire project by choosing the “Only 
Transfer Files that have Changed” option. Here again, browse to the .web 
project folder and select the default page. Click Open, and then OK to transfer 
the changed files. 
Finally, selecting “Transfer Single File” can send a single HTML file. Browse to 
the file and click Open. Then specify the file’s relative path (from the root 
directory) and click OK
NOTE:  For Crestron e-Control 2, you can choose the default “Main.HTML” 
name or you can change the name. 
SIMPL Windows 
For each IP ID in the VT Pro-e browser project, there must be one 
corresponding Crestron e-Control PC Interface symbol defined in the SIMPL 
Windows program. The PC Interface symbol is one of the Ethernet Modules that 
can be dropped into the C2ENET-1 card slot.  
As with all Ethernet devices, the PC Interface must receive an entry in the IP 
Table of the QM-RMCRX. Here the IP ID must match the IP ID that was 
assigned in VT Pro-e, while the IP address must be set to a loopback: 127.0.0.1, 
when hosting internal. 
Converting Programs and Modules Created for 
Other Systems 
A useful feature of SIMPL Windows is that you can convert a program created 
for another type of control system, simply by changing the target to a QM-
RMCRX.  
To do this you first open the program, and then replace the existing control 
system with the QM-RMCRX. That is, drag the QM-RMCRX from the Control 
Systems folder onto the existing control system in System Views, and click Yes 
when prompted to confirm the replacement. 
If the program contains SIMPL+ or User modules, the conversion might 
generate error messages. This is because modules and programs often contain 
symbols with “ambiguous” signals. For example, the inputs of the Serial to 
Analog symbol can be defined as either analog or serial. Although X-Generation 
processors support ambiguous signals, the 2-Series processor requires all signal 
types to be strictly defined. 
50 
 QuickMedia™ Receiver/Processor: QM-RMCRX 
Operations Guide - DOC. 6236A