Omron r53 Benutzerhandbuch

Seite von 2
3.4  Using the Memory Function
The unit automatically stores up to 60 sets of measurement 
values (blood pressure and pulse rate).
It can also calculate an average reading based on the 
measurements from the last three readings taken within 10 
minutes. If there are only two readings in memory for that 
period, the average will be based on two readings. If there is 
one reading in memory for that period, the average will be 
based on one reading.
Notes:
• If the memory is full, the monitor will delete the oldest 
readings.
• When viewing the reading taken without setting the date and 
time, “-:--” is displayed instead of the date and time.
To View the Average Value
To View the Readings Stored in Memory
To Delete All the Values Stored in Memory
Note: You cannot partially delete the stored readings.
4.1  The Icons and Error Messages
Note: The irregular heartbeat symbol (
) may also be displayed 
with error messages.
4.2  Troubleshooting
4.3  Maintenance
To protect your unit from damage, please observe the 
following:
• Do not subject the main unit and the cuff to 
extreme temperatures, humidity, moisture or 
direct sunlight.
• Do not disassemble the unit.
• Do not subject the unit to strong shocks or 
vibrations (for example, dropping the unit on the 
floor).
• Do not use volatile liquids to clean the main unit.
• Do not wash the cuff or immerse it in water.
• Do not use petrol, thinners or similar solvents to 
clean the cuff.
• Do not carry out repairs of any kind yourself. If a 
defect occurs, consult your OMRON retail outlet 
or distributor as mentioned on the packaging.
• The unit should be cleaned with a soft, dry cloth.
• Use a soft, moistened cloth and soap to clean 
the cuff.
• Keep the unit in its storage case when not in 
use.
• Fold the cuff into the storage case.
Do not store the unit in the following situations:
• If the unit is wet.
• Locations exposed to extreme temperatures, 
humidity, direct sunlight, dust or corrosive 
vapours.
• Locations exposed to vibrations, shocks or 
where it will be at an angle.
Calibration and Service
• The accuracy of this blood pressure monitor has 
been carefully tested and is designed for a long 
service life.
• It is generally recommended to have the unit 
inspected every two years to ensure correct 
functioning and accuracy. Please consult your 
authorised OMRON dealer or the OMRON 
Customer Service at the address given on the 
packaging or attached literature. 
Note: Subject to technical modification without prior notice. 
• This device fulfils the provisions of EC directive 93/42/EEC 
(Medical Device Directive). 
• This blood pressure monitor is designed according to the European 
Standard EN1060, Non-invasive sphygmomanometers Part 1: 
General Requirements and Part 3: Supplementary requirements 
for electromechanical blood pressure measuring systems.
• This OMRON product is produced under the strict quality system of 
OMRON HEALTHCARE Co. Ltd., Japan. The Core component for 
OMRON blood pressure monitors, which is the Pressure Sensor, is 
produced in Japan.
Made in China
Press the Memory button.
 
Note: If there are no measurements 
results stored in the memory, the 
screen to the right is displayed.
 
1.
Press the 
 button, while the average value is 
displayed.
The Memory number 
appears for a second 
before the pulse rate is 
displayed. The newest 
set is numbered “1”.
 
2.
Press the 
 button repeatedly to view the 
readings stored in memory.
When the memory symbol  (
) appears, first press 
the 
 button. Then while holding it down, press the 
START/STOP button simultaneously for about 2 - 3 
seconds.
Error Display
Cause
Remedy
Irregular heartbeats 
are detected.
Remove the wrist cuff. Wait 
2 - 3 minutes and then take 
another measurement.
Repeat the steps in section 
3.3. If this error continues to 
appear, contact your doctor.
Movement during 
measurement.
Carefully read and repeat the 
steps in section 3.3.
Blink
The batteries are 
low.
You should replace them with 
new ones ahead of time.
Refer to section 2.1.
Lit
The batteries are 
exhausted. 
You should replace them with 
new ones at once.
Refer to section 2.1.
Wrist cuff not 
applied correctly.
Apply the wrist cuff correctly.
Refer to section 3.1.
Movement during 
measurement.
Repeat Measurement while 
remaining still and refraining 
from talking during the 
measurement.
Refer to section 3.3.
Wrist cuff not 
applied correctly, or 
movement during 
measurement.
Apply the wrist cuff correctly 
and repeat measurement 
while remaining still and 
refraining from talking during 
the measurement.
Refer to section 3.1 and 3.3.
Device error.
Contact your OMRON retail 
outlet or distributor.
Alternating 
date/time 
display
First
Second
4.  Troubleshooting and Maintenance
Problem
Cause
Remedy
The reading is 
extremely low 
(or high).
The wrist cuff is not 
at heart level.
Measure while in the 
correct posture.
Refer to section 3.2.
The cuff is not 
wrapped snugly 
around the wrist.
Wrap the cuff correctly.
Refer to section 3.1.
The arms and 
shoulders are 
tense.
Relax and try taking the 
measurement again.
Refer to section 3.3.
Movement or 
talking during 
measurement.
Remain still and do not 
talk during Measurement.
Refer to section 3.3.
Wrist cuff pressure 
does not rise.
Air is leaking from 
the wrist cuff.
Consult your OMRON 
retail outlet or distributor.
Wrist cuff deflates 
too soon.
The wrist cuff is 
loose.
Apply the cuff correctly so 
that it is firmly wrapped 
around the wrist. Refer to 
section 3.1.
The blood pressure is different 
each time. The reading is 
extremely low (or high).
Blood pressure readings 
constantly vary with time 
of day and how relaxed 
you are. Take several 
deep breaths and try to 
remain relaxed before 
taking a measurement.
The unit loses 
power during 
measurement.
The batteries are 
exhausted.
Replace the batteries with 
new ones.
Refer to section 2.1.
Nothing happens 
when you press 
the buttons.
The batteries have 
been inserted 
incorrectly.
Insert the batteries with 
the correct (+/-) polarity.
Refer to section 2.1.
Other problems.
• Press the START/STOP button and repeat 
measurement.
• If the problem continues, try replacing the 
batteries with new ones.
If this still does not solve the problem, contact 
your OMRON retail outlet or distributor.
Product Description
Wrist Blood Pressure Monitor
Model
OMRON RS3 (HEM-6130-E)
Display
LCD Digital Display
Measurement Method
Oscillometric method
Measurement Range
Pressure: 0 to 299 mmHg 
Pulse: 40 to 180/min.
Accuracy
Pressure: ±3 mmHg 
Pulse: ±5% of display reading
Inflation
Automatic inflation by pump
Deflation
Automatic rapid deflation
Memory
60 Measurements
Power Source
2 “AAA” alkaline (LR03) batteries 1.5V 
Battery Life
Approx. 300 measurements with new 
alkaline batteries at a room temperature of 
23°C
Applied Part
= Type B
Protection Against 
Electric Shock
Internally powered ME equipment
Operating temperature/ 
Humidity
+10 to +40°C / Maximum: 30 to 85% RH
Storage temperature/ 
Humidity
-20 to +60°C / Maximum: 10 to 95% RH / 
700 to 1060hPa
Console Weight
Approximately 101g without batteries
Outer Dimensions
Approximately 78 (w) mm x 60 (h) mm x 
21 (d) mm (without the wrist cuff)
Measurable 
circumference
Approximately 13.5 to 21.5 cm
Cuff Material
Nylon and polyester
Package Content
Main unit, storage case, battery set, 
instruction manual, guarantee card
Important information regarding Electro Magnetic 
Compatibility (EMC)
With the increased number of electronic devices such as PC’s and 
mobile (cellular) telephones, medical devices in use may be 
susceptible to electromagnetic interference from other devices. 
Electromagnetic interference may result in incorrect operation of 
the medical device and create a potentially unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic 
Compatibility) with the aim to prevent unsafe product situations, the 
EN60601-1-2:2007 standard has been implemented. This standard 
defines the levels of immunity to electromagnetic interferences as 
well as maximum levels of electromagnetic emissions for medical 
devices.
This medical device manufactured by OMRON HEALTHCARE 
conforms to this EN60601-1-2:2007 standard for both immunity and 
emissions.
Nevertheless, special precautions need to be observed:
• Do not use mobile (cellular) telephones and other devices, which 
generate strong electrical or electromagnetic fields, near the 
medical device. This may result in incorrect operation of the unit 
and create a potentially unsafe situation. Recommendation is to 
keep a minimum distance of 7 m. Verify correct operation of the 
device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is 
available at OMRON HEALTHCARE EUROPE at the address 
mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.
Correct Disposal of This Product 
(Waste Electrical & Electronic Equipment)
This marking shown on the product or its 
literature, indicates that it should not be 
disposed of, with other household wastes at the 
end of its working life. 
To prevent possible harm to the environment or human health from 
uncontrolled waste disposal, please separate this product from 
other types of wastes and recycle it responsibly to promote the 
sustainable reuse of material resources.
Household users should contact either the retailer where they 
purchased this product, or their local government office, for details 
of where and how they can return this item for environmentally safe 
recycling.
Business users should contact their supplier and check the terms 
and conditions of the purchase contract. This product should not be 
mixed with other commercial wastes for disposal. 
Manufacturer
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, Kyoto, 
617-0002 JAPAN
EU-representative
OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp 
THE NETHERLANDS
www.omron-healthcare.com
Production facility
OMRON (DALIAN) CO., LTD.
Dalian, CHINA
Subsidiary
OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes, MK15 0DG 
U.K.
OMRON MEDIZINTECHNIK 
HANDELSGESELLSCHAFT mbH
John-Deere-Str. 81a, 68163 Mannheim, GERMANY
www.omron-medizintechnik.de
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 
Rosny-sous-Bois Cedex, FRANCE
5.  Technical Data