Address Description 
Range 
Default Comment 
60 
and 
61 
Left Brew Valve 
    Flow Rate 
Right Brew Valve 
    Flow Rate 
0.09 – 1.49 
If #59 is GAL
 
 
or 
 
0.33 – 5.63 
If #59 is LTR
 
0.92 
 
 
 
 
3.48 
62 
and 
63 
Left Bypass Valve 
    Flow Rate 
Right Bypass 
    Valve Flow Rate 
 
0.28 – 0.38 
If #59 is GAL
 
 
or 
 
1.05 – 1.44 
If #59 is LTR
 
0.33 
 
 
 
 
1.24 
 
 
Use this to compensate for minor discrepancies in 
actual volume versus programmed volume.  Set 
lower to increase volume, higher to decrease 
volume. The following formula can be used to 
determine the correct setting: 
 
ACTUAL VOLUME 
PROGRAMMED VOLUME 
X
CURRENT 
SETTING 
NEW 
SETTING 
 
64 
Keypad Test 
0 - 1 
Tests function of control panel switches. 
0 - Skip keypad test 
1 - Keypad test active 
Starting at the stop buttons, press each button 
that is lit. The display will show the name of the 
switch being pressed. Brew switches are named 
S1, S2, S3, etc. The hot water switch must be 
pressed last, as this will exit the test. 
65 
Relay Test 
0 - 1 
0 - Skip relay test. Loop back to #50 
1 – Relay test active. 
 
Press STOP to continue 
 
Press        to save the settings and exit Diagnostic mode. 
 
Press        again to exit Programming mode and return to Operating mode. 
 
 
Relay Test 
Tests the individual relays which control various components. 
Use either batch button to actuate the relays. 
 
 
To begin, you must first press the blinking Control Panel Power Switch. 
Address Description 
Comment 
90 
Left or Single Brew Valve 
 
91 
Right Brew Valve 
 
92 
Left or Single Bypass Valve 
 
93 
Right Bypass Valve 
 
94 
Hot Water Faucet 
 
95 Fill 
Valve 
 
96 
Heater 
To protect the heaters, this test will work only if the tank is full. 
97 
Left or Single Brew Basket Lock 
 
98 
Right Brew Basket Lock 
 
 
Press        to exit Relay Test. 
 
Press        again to exit Diagnostic mode. 
 
Press        again to exit Programming mode and return to Operating mode. 
 
 
             
Warning: During these 
                  tests, hot water may 
                  be dispensed from 