KVH Industries TracVision L2 Benutzerhandbuch

Seite von 69
E-2
A Guide to TracVision L2
*** Entering Tracking ***
+POS:  61.8  36.5 1260
+POS:  62.2  36.3 1346
+POS:  64.0  36.5 1716
*** Entering Satellite Check ***  --------Confirming proper satellite lock
+POS:  64.3  36.1 1747
Satellite Located
IRD Signal Quality = 54
+POS:  66.1  35.6 1522
+POS:  64.6  35.5 1749
IRD Signal Quality = 58           
+POS:  66.2  36.1 1467            
+POS:  64.5  35.8 1757
“Instant On” Startup Sequence
?PGM
KVH TracVision L2 Rev X - Version X.XX - Serial Number XXXXXXXX
Instant On --------------------------------System skips limit switch test
Limit Switch Status: PASS-----------------PASS is expected
*** Initializing IRD ***
...
IRD STATUS: PASS  DSS --------------------PASS is expected with successful IRD
identification
Saved Sat Pos: EL = 33.3
*** Initializing Rate Bias ***
+POS:  360.0  33.9  2625
VEL_INDEX: Az = 1996, El = 2182  ---------Expected range is 1700-2300
RATE BIAS: PASS --------------------------Az & El values above are within valid ranges
*** Initializing Finetune ***-------------Peaking the satellite signal
+POS: 360.0  33.9 2622
Signal Peaked: AZ =   0.00, EL =  33.30, RF = 2674
+POS:   0.0  33.3 2646
+POS:   0.0  33.3 2638
IRD Signal Quality = 79 
+POS:   0.0  33.3 2640
+POS:   0.0  33.3 2614
IRD Signal Quality = 77 
CH = 200 XP = 7 HI = 0 LO = 10
+POS:   0.0  33.3 2652
Saved Sat Pos: AZ =   0.00, EL =  33.30
+POS:   0.0  33.3 2617
+POS:   0.0  33.3 2616
IRD Signal Quality = 78 
+POS:   0.0  33.3 2610