FOR OUTDOOR USE ONLY
NOT FOR USE IN HAZARDOUS ATMOSPHERES
IMPORTANT:      Read instruction sheet carefully before installing fixture.
Retain instructions for future reference.
ELECTRICAL REQUIREMENTS
A qualified electrician should complete all required wiring. This fixture will accept 120, 208, 240 or 277 
Volts AC and must be properly grounded for safety. A mounting suitable for outdoor use and rated for 
wet locations is required. Follow all applicable electrical codes and regulations
.
WARNING:
Electric shock hazard
Disconnect power at circuit breaker or fuse box before installing or servicing light.
WARNING:
Fire hazard
USE MIN 60ºC SUPPLY CONDUCTORS.
CONNECT TO SUPPLY IN EXTERNAL JUNCTION BOX ONLY.
Lamp and housing become very hot during use.
Ensure free air circulation around unit to dissipate heat.
Avoid enclosed locations and locations where flammable debris (leaves, cut grass, etc.) might collect.
Avoid locations where humans or animals might accidentally touch fixture.
WARNING:
Explosion hazard
Never operate light without securing the lens door. When light is operating, the gas in the lamp inner arc tube 
is at high pressure.
Never operate light if the fixture lens or outer glass envelope of the lamp is broken or missing.
WARNING:
Explosion hazard
Wear safety glasses and gloves when handling lamp, High Pressure Sodium outer envelope is under vacuum 
and could implode.
MOUNTING & WIRING
1. Screw the threaded mounting arm of the fixture into 1/2” NPS mounting hole on mounting device.
Tighten locknut to secure fixture. See Figure 1.
CAUTION:
Mount the fixture so lamp is horizontal. (See Figure 2)
HID Flood Light - FL Series
INSTALLATION INSTRUCTIONS
Lamp Types: High Pressure Sodium 100 Watt
Models: FL100HPS
Figure 1
Figure 2
Install with lamp horizontal
Clip
Lens 
Cover
Hinge
Mounting
Arm Bolt
Locknut