Zebra Technologies R110Xi Benutzerhandbuch

Seite von 184
RFID Guidelines
^WT
23063L-003 Rev. 1 12/6/04
R110Xi/R170Xi User Guide
95
^WT
Write Tag
Description  This command allows you to program the current RFID tag.
Format  
^WTb,r,m,w,f,v
The following table identifies the parameters for this format.
Note • 
It is recommended that you use the 
^RF
^RM
^RR
, and 
^WV
 commands rather than 
the 
^WT
 command. The 
^WT
 command is provided only for backward-compatibility with 
label formats that were developed for other Zebra RFID printers.
Important • 
Check the amount of data memory available for the tag that you will be using. If 
more is sent than the memory can hold, the printer truncates the data.
Parameters
Details
b
= block number
This parameter is tag-dependent. For most tags, use block 0. For EPC Class 0 Plus, 
block 0 is EPC data, and block 1 is user data (both are 96 bits).
Accepted values: 0 to n, where n is the maximum number of blocks for the tag.
Default value: 0
r
= number of 
retries
Changes the number of times that the printer attempts to write to a particular block of 
a single RFID tag. (Same function as the 
^RR
 command.)
Accepted values: 0 to 10
Default value: 0
m
= motion
Enables or disables RFID motion. (Same function as the 
^RM
 command.)
Accepted values:
• 0 (Feed label after writing.)
• 1 (No Feed after writing. Other ZPL may cause a feed.)
Default value: 0
w
= write protect
Accepted values:
• 0 (Not write protected.)
• 1 (Write protect.)
Default value: 0