11.0  automatic Filtration Cycles
Your new spa includes a 24-hour circulation pump which filters the water 
continuously. The circulation pump draws water through the skimmer bag 
and one of two filter cartridges to effectively remove small debris in your spa. 
note: The 24-hour circulation pump system also supplies heated water 
to the spa when the heater turns on. The pump is not programmable.
The control system activates a programmable “Standard” or “Economy” 
filtration/heating cycle to remove larger debris missed by the 24-hour 
circulation pump filtration system. These cycles utilize pump #1 low 
speed and the second filter cartridge to quickly “skim” the water of large 
debris and minimize their “bath-tub ring” effect. Apart from their skimming 
benefit, each mode also effects the operation of your spa’s heater. Refer 
to Sections 11.1 and 11.2 below for additional information.
11.1 
standard Filtration/heating Modes (F0-F3)
Standard filtration/heating modes are typically selected by customers in 
cold climates where heat up times are extended due to lower ambient 
temperatures. In these modes, the water temperature is regulated by the 
set temperature, 24-hour circulation pump, and heater which turns on as 
needed. After the programmed set temperature is reached, the heater 
turns off and the circulation pump continues to operate 24-hours to filter 
and clean your spa unless in summer logic; see Section 14.1, page 38.
11.2 
economy Filtration/heating Modes (F4-F6)
Economy filtration/heating modes are typically selected by customers in 
warm climates where heat up times are minimized due to higher ambient 
temperatures. In these modes, the water temperature is regulated by 
the set temperature, 24-hour circulation pump, and heater only while a 
programmed filter cycle is running (unless in summer logic; see Section 
11.3 
lock modes (l1-l2)
These modes are designed for use during spa service or to prevent 
unauthorized use.
11.4 
selecting the Filtration/heating Mode
Press and hold both control panel WARMER ( ) and COOLER ( ) 
buttons at the same time, then release. Then press either WARMER  
( ) or COOLER ( ) button to select filtration/heating mode F0-F6 or 
lock modes L1-L2 below: