DSC pc1616 Benutzerhandbuch

Seite von 64
PowerSeries - PC1616/PC1832/PC1864
22
Section [701] First International Option Code
Section [702] Second International Option Code
Section [703] Delay Between Dialing Attempts
Program the time the panel will wait between dialing attempts to transmit a reporting event to the central station. 
Valid entries are [001] to [255].
Section [800]-[851] Module Programming
The following program sections are used to program different modules that can be connected to the control panel.  Refer to the respective 
Installation Manual for installation and programming information
Section [801]:
PC5400 Printer Module Programming
Section [802]:
PC59xx VOX Module Programming
Section [803]:
Alternate Communicator Programming
Section [804]:
Wireless Programming
Section [805]:
PC5100 Addressable Programming
Section [851]:
T-Link Programming
Option
Description
 [1]
ON: configures the system for 50Hz AC.  OFF: configures the system for 60Hz AC.
 [2]
ON: the system uses the internal crystal for the internal panel clock.  OFF: the system uses the AC frequency for the internal panel clock.
 [3]
ON: the system will inhibit arming if a Low Battery or AC trouble condition is present.  OFF: arming will not be inhibited.
 [4]
ON: all Tamper troubles will latch and arming will be inhibited.  Enter Installer Programming to clear the trouble condition and return to 
normal operation.  OFF: tamper troubles will not latch and will not inhibit arming.
 [5]
ON: all access codes are 6 digits long. OFF: all access codes are 4 digits long.
 [6]
ON: the system will hang up if a busy tone is detected.  This attempt is not counted towards the Maximum Dialing Attempts programmed.  
OFF: the panel will not detect busy tones. 
 [7]
ON: the system will charge the battery at approximately 700mA.  OFF: the system will charge the battery at 400mA.
 [8]
ON: the system will abort a DLS session, Escort access, Listen In/Two-way session if a new central station communication event occurs.  
OFF: non-critical events (Test transmission, Periodic Test and System Test) will not abort the session.  Events will be communicated after 
the session is complete.
Option
Description
 [1]
ON: the communicator uses 33/67 make/break ratio when pulse dialing.  OFF: the system uses 40/60 make/break ratio.
 [2]
ON: the system dials regardless of the presence of dial tone after the first attempt.  OFF: the system dials only if dial tone is detected.
 [3]
ON: changes the Test Transmission Cycle Time to minutes.  OFF:  sends a Test Transmission after the programmed number of days.
 [4]
ON: the system accepts 1600Hz handshake pulse formats.  OFF: the system accepts 1400Hz or 2300Hz handshakes.
 [5]
ON: the system generates a tone for 500mS every 2 seconds indicating digital equipment is making the call vs. a voice call.  
OFF: the system does not generate a tone.
 [6]
ON: the tone generated (2100Hz.) indicates that digital equipment is making the call.  OFF: the tone is  1300Hz.
 [7]
ON: the DLS dowloading window is 1 hour. OFF: the DLS downloading window is 6 hours.
 [8]
ON: the system activates the bell output if a Failure to Communicate trouble occurs while the system is armed.  
OFF: the system does NOT activate the bell output if a Failure to Communicate trouble occurs while the system is armed.