are  integrally  attached.  If  standoff  spacers 
are attached to your firebox, these spacers 
can be placed directly against wall or fram-
ing materials.
Use the dimensions shown for rough openings 
to create the easiest installation (see Built-In 
Firebox Installation
, page 10).
INstAllAtIoN cleARANces
  WARNING:  Maintain  the 
minimum  clearances.  if  you 
can, provide greater clearances 
from floor, ceiling and adjoining 
wall.
Carefully follow the instructions below. This 
will ensure safe installation.
Minimum clearances For side 
combustible material, side wall and 
ceiling
A.  Clearances from side of fireplace cabinet 
to  any  combustible  material  and  wall 
should follow diagram in Figure 6.
 
Example: The face of a mantel, bookshelf, 
etc. is made of combustible material and 
protrudes 3 
1
/
2
" from the wall. This com-
bustible material must be 4" from side of 
fireplace opening (see Figure 6).
B.  Clearances from top of fireplace opening 
to ceiling should not be less than 42".
INSTALLATION
Figure 6 - Minimum Clearance for 
Combustible to Wall
*Minimum 16" from Side Wall
*
Example
NotIce: this heater is intended 
for  use  as  supplemental  heat. 
use this heater along with your 
primary heating system. do not 
install  this  heater  as  your  pri-
mary heat source. if you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. this will help 
circulate the heat throughout the 
house. in the event of a power 
outage, you can use this heater 
as your primary heat source.
 warNiNG: a qualified ser-
vice person must install firebox. 
follow all local codes.
 WARNING: Never install the 
firebox
•  in a bedroom or bathroom
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing  or  other  flammable 
objects are less than 42" from 
the front, top or sides of the 
firebox
•  in high traffic areas
IMPORTANT: Vent-free gas log heaters add 
moisture to the air. Although this is beneficial, 
installing  firebox  in  rooms  without  enough 
ventilation air may cause mildew to form from 
too much moisture. See Air for Combustion 
and Ventilation
, page 4.
IMPORTANT: Make sure the firebox is level. 
If  firebox  is  not  level,  log  set  will  not  work 
properly.
Note: Your firebox is designed to be used in 
zero clearance installations. Wall or framing 
material  can  be  placed  directly  against  any 
exterior surface on the rear, sides or top of 
your firebox, except where standoff spacers