Clifford remote start & security system 520.4x Benutzerhandbuch

Seite von 53
26
© 2011 Directed Electronics. All rights reserved.
Trigger Zone Fault Report
When armed by remote command the system runs a status check 
of the alarm trigger zones. Faulty zones (usually caused by dome 
light delay or open trunk) are bypassed and reported via the control 
center LED and remote, while all other trigger zones remain active 
and are monitored to protect the vehicle. Should a faulty zone self 
correct (dome light turns off) it becomes active and is then monitored 
normally. 
The siren chirps once again a few seconds following the arming 
chirps as an audible alert, the control center LED flashes in groups to 
indicate the zone number. 
Alarm Report
If the alarm was triggered while armed, it will be reported when 
the alarm is disarmed via the remote control, siren chirps, parking light 
and control center LED flashes. The siren chirps 4 times (or 5 times if 
NPC On*), the parking lights flash 3 times, and the control center LED 
flashes in groups to indicate the last two zones that were triggered 
(see Table of Zones). The report output will repeat for each disarm 
operation until the ignition is turned on.
* See 
Nuisance Prevention (NPC)
 for more details.