Bosch ndn-921 Benutzerhandbuch

Seite von 134
FlexiDomeHD 720p IP Camera
Installation | en
29
Bosch Security Systems
Installation and Operation Manual
AR18-10-B013 | v1.52 | 2011.06
5.3
Connections
5.3.1
Make the connections
The unit has connection terminals on flying leads. In wet or 
outdoor installations make use of a field wiring box with Nema3 
or IP55 protection level or better. Make the connections inside 
the water tight compartment. After connections are made 
ensure that the watertight compartment is tightly closed and 
cables and conduits are properly sealed to prevent ingress of 
water.
Cable tree
Use the following table to identify the wires in the cable tree:
Power connection
1.
Use a class 2 power supply 24 VAC or +12 VDC.
2.
Connect the power wires (red+ , brown-) to the power 
supply connector.
3.
Connect the earth wire (yellow/green) 
 from the 
camera to the system earth of the installation to ensure 
correct EMC/RFI and safety protection.
Wire color
Signal
Red
+12 VDC / 24 VAC
Brown
GND DC / 24 VAC
Yellow / Green
Earth 
Black / Orange
Alarm Out A
White / Orange
Alarm Out B
Violet
Alarm In
White / Violet
Ground (Alarm In)
White
Audio In
(Shield)
Ground (Audio In)
Black Audio 
Out
(Shield)
Ground (Audio Out)