FMI GL36STE Benutzerhandbuch

Seite von 20
www.fmiproducts.com
55173H
17
TROUBLESHOOTING
MILLIVOLT SYSTEM
Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. 
The two most common causes of a malfunctioning gas appliance are:
1.  Loose wiring connections
2.  Construction debris clogging the pilot and/or gas control valve filter
OBSERVED PROBLEM
Pilot will not light
Pilot will not stay lit
No gas to burner, although wall 
switch  and  valve  are  set  to  the 
ON position
Frequent pilot outage
Pilot goes out when wall switch 
is ON
POSSIBLE CAUSE
1. No  gas  supply  or  shutoff 
valve is OFF
2. Air in gas line
3. Construction  debris  clog-
ging pilot orifice
4. Low gas pressure
5. Control valve knob is not on 
the PILOT position
6. Kinked pilot line
7. Bad valve
1. Loose wiring on thermopile 
to control valve. 
2. No millivolt current is being 
sent back to regulator
3. If valve knob and wall switch 
are in the ON position, prob-
able defective control valve
1. Wall switch wires defective
2. Thermopile  or  sensor  not 
generating sufficient voltage
1. Pilot  flame  may  be  too 
low, causing safety pilot to 
“drop out”
1. Millivolt output on thermo-
pile too high
REMEDY
1. Check to see if you have gas 
supply
2. Hold regulator control valve 
in the PILOT position for 2 to 
3 minutes to purge air. If you 
smell gas stop and wait for a 
few minutes before trying to 
light the fireplace
3. Remove  debris  and  dirt,  in-
spect  and  clean  any  other 
possible obstructions
4. Contact your gas supplier
5. Refer  to  section  on  pilot 
lighting
6. Have  a  qualified  technician 
replace pilot line
7. Replace  control  valve  (see 
Replacement Parts, page 19)
1. Check  wiring  connections. 
Refer to wiring diagrams on 
page 15
2. Have  a  qualified  technician 
check millivolts
3. Have  a  qualified  technician 
replace  valve  (see  Replace-
ment Parts and Accessories
page 19)
1. Check electrical connections 
and wires for continuity
2. See  Pilot  will  not  stay  lit
above
1. Clean and adjust pilot flame 
for maximum flame impinge-
ment on thermopile
1. Have  a  qualified  technician 
replace thermopile