Troubleshooting 
Brewing Problem 
Possible Cause 
Solution 
 Brew switch will not start brew cycle (no water 
is dispensed) 
and brew light does not come on, 
even when switch is pressed in. 
No power to the brewer 
(Brewer lights are not illuminated) 
-Make sure power switch is on 
-Check power connection. (plug or hard wire 
connection) 
-Check the wall circuit breaker / reset 
-Reset the circuit breaker, located on the back of the 
brewer.  Press and release the white button. 
 
Bad brew switch 
-Replace switch. 
and brew light does not stay on. 
(Light is on only while switch is 
pressed in.) 
Bad timer or stop switch. (The 
stop switch provides voltage to 
the timer.) 
-Check for voltage reaching the timer.  If voltage is 
present, replace timer.  If not, replace stop switch. 
Brew switch will not start brew cycle (no water 
is dispensed) 
and brew light does come on. 
No water reaching the brewer.  
Verify by dispensing water from 
hot water faucet for several 
seconds. Water should flow 
freely and steadily. 
-Make sure the shut off valve is open. 
-Check water line for kinks; replace line if necessary 
-Check to see if filter is clogged by changing it. 
 
Bad dispense valve. (Brewer may 
buzz when in brew cycle) 
-Replace the dispense valve 
Short brew levels  EVERY BREW 
Water filter clogged 
(See details in next section) 
 
Dispense valve clogged 
-Clean and/or replace the dispense valve. 
(One or both sides are affected and levels are 
Timer/s are set too low 
-Advance timers to proper level. 
 consistent
Incoming Voltage is too low for 
timers to function at proper time 
sequences 
-Reset wall circuit breaker as one side may drop out & 
not flag the breaker. 
-Call an electrician to find loose connections in the 
building 
Short brew levels  SOME BREWS  
 
Water filter clogged. 
(problem is worse during 
simultaneous brews) 
-Replace water filter 
(One or Both sides are affected and levels are 
erratic
Weak dispense valve 
(may buzz during cycle) 
-Replace dispense valve. 
 
Water pressure or flow rate is too 
low or fluctuates too much to 
support a full brew. 
(problem is worse during 
simultaneous brews) 
-Make sure brewer has a dedicated water line 
-Ensure that the shut off valve is open all the way 
(Never use needle saddle valves) 
-Increase the diameter of the water line to the brewer 
and or find stable source. 
Brew time required to fill dispensers is not 
the same for both sides 
Brewer is not level 
-With an accurate level, level the brewer front to back 
and left to right by adjusting the feet. 
High brew levels    EVERY BREW  
(overfills but eventually does stop) 
Timer/s are set too high 
-Adjust timers down to appropriate level 
                               SOME BREWS 
Dispenser not empty 
-Empty the dispenser and try again 
Brew basket or filter overflows 
 
-Call FETCO Service Dept. to discuss. 
    (800) 338-2699 
Weak Coffee 
Improper dose 
-Measure and confirm correct dose 
 
Too many filter papers 
-Make sure only one paper is used 
 
Low brew temperature 
(Temperature inside the hot 
water tank should be set to 205
° 
F.) 
-Adjust thermostat so the water stream measured at 
the bottom of the brew basket, 1/3 of the way 
through the brew cycle, equals 195 degrees + or - 5 
degrees 
Grounds not saturated 
Half batch used incorrectly 
-Use smaller brew basket 
 
 
-Discourage half batch use  
 
Water Softener in use 
-Move brewer water feed to a non-softened source. 
 
Degassing - extremely fresh 
coffee 
-Call FETCO Service Dept. to discuss. 
    (800) 338-2699 
Spray head / brew basket drips  - MAJOR or 
MINOR 
one side only 
Dispense valve not sealing 
properly. 
-Clean, rebuild, or replace dispense valve. 
Spray head / brew basket drips  - MAJOR or 
MINOR 
double brewers - right side only 
Fill valve not sealing 
(Will drip even with power off.) 
-See next section - “Brewer won’t stop brewing”, “Bad 