FMI pfs p325e(b) Benutzerhandbuch

Seite von 32
www.fmiproducts.com
108794-01G
23
trouBlesHootING
Continued
WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your
building.
•  Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning 
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, 
etc., create fumes. These fumes may mix with combustion air and create odors. 
OBSERVED PROBLEM
No  gas  to  burner,  although 
wall switch and valve are set 
to the ON position
Frequent pilot outage
Fireplace produces a clicking/
ticking noise after burner is lit 
or shut off
Fireplace produces unwanted 
odors
Gas odor even when equip-
ment shutoff valve is in OFF 
position
Gas odor during combustion
POSSIBLE CAUSE
1. Wall switch wires defective 
or too long
2. Thermopile not generating 
sufficient voltage
1. Pilot flame may be too low, 
causing safety pilot to “drop 
out”
2. Improper venting or exces-
sive blockage
1. Metal  expanding  while 
heating or contracting while 
cooling
1. Fireplace  burning  vapors 
from  paint,  hair  spray, 
glues,  etc.  (See  IMPOR-
TANT statement above)
2. For  propane/LP  gas,  low 
fuel supply
3. Gas  leak. 
See  Warning 
statement at top of page
1. Gas  leak.
  See  Warning 
statement at top of page
2. Control valve defective
1. Foreign  matter  between 
control valve and burner
2. Gas  leak. 
See  Warning 
statement at top of page
REMEDY
1. Check  electrical  connec-
tions
2. See  Pilot  will  not  stay  lit
page 22
1. Clean and adjust pilot flame 
for  maximum  flame  im-
pingement on thermopile
2. Have  the  vent  system  in-
spected, including the ter-
mination cap. Remove any 
restriction or obstruction
1. This  is  normal  with  most 
fireplaces.  If  noise  is  ex-
cessive,  contact  qualified 
service person
1. Ventilate  room.  Stop  us-
ing odor causing products 
while fireplace is running
2. Contact  local  propane/LP 
supplier
3. Locate and correct all leaks 
(see  Gas  Line  Hook-Up
page 12)
1. Locate and correct all leaks 
(see  Gas  Line  Hook-Up
page 12)
2. Replace control valve
1. Take apart gas tubing and 
remove foreign matter
2. Locate and correct all leaks 
(see  Gas  Line  Hook-Up
page 12)