FMI pfs p325e(b) Benutzerhandbuch

Seite von 32
www.fmiproducts.com
108794-01G
6
ProduCt sPeCIFICAtIoNs
Figure 2 - Appliance Dimensions
7
/
8
"
1
/
4
"
7"
7"
Alternate Gas
Supply Inlet
13 
1
/
4
"
32 
1
/
4
"
* 27 
1
/
2
"
29"
* 13 
3
/
4
"
14 
1
/
2
"
* 20 
3
/
8
"
21 
1
/
2
"
1
/
2
"
1
/
4
"
11 
3
/
4
"
22 
3
/
8
"
For Use
With B-1
Vent Pipe
Only
16 
3
/
4
"
5
/
8
"
10 
5
/
8
"
1
/
8
"
10 
1
/
2
"
3
/
8
"
1
/
2
"
1
/
4
"
5/8"
34 
1
/
2
"
35 
3
/
8
"
29 
1
/
2
"
18 
1
/
4
"
7"
7"
16 
3
/
4
"
36 
1
/
2
"
* WITH REFRACTORY
DIMENSIONS
HEARTH AREA
GAS RATING - NATURAL
P324E, VP324E
P325E(B), VP325E(B)
Max. Input Rating:
15,000 Btu/Hr
25,000 Btu/Hr
Manifold Pressure:
3.5" WC (.87 kPa)
3.5" WC (.87 kPa)
Minimum Supply Pressure:
4.5" WC (1.12 kPa)
4.5" WC (1.12 kPa)
Maximum Supply Pressure:
10.5" WC (2.66 kPa)
10.5" WC (2.66 kPa)
Orifice Size:
# 49
# 40
GAS RATING - PROPANE/LP
Max. Input Rating:
15,000 Btu/Hr
25,000 Btu/Hr
Manifold Pressure:
10" WC (2.49 kPa)
10" WC (2.49 kPa)
Minimum Supply Pressure:
11" WC (2.74 kPa)
11" WC (2.74 kPa)
Maximum Supply Pressure:
13" WC (3.23 kPa)
13" WC (3.23 kPa)
Orifice Size:
# 56