Furuno 1943C Benutzerhandbuch

Seite von 251
7. MAINTENANCE, TROUBLESHOOTING 
 
 
 7-3
7.5 Simple 
Troubleshooting 
This section provides simple troubleshooting procedures which the user can 
follow to restore normal operation. If you cannot restore normal operation do not 
attempt to check inside the unit. Any trouble should be referred to a qualified 
technician.  
 
7.5.1 General 
General troubleshooting 
If… Then… 
you cannot turn on the 
power 
• 
check for blown fuse. 
• 
check that the power connector is firmly fastened. 
• 
check for corrosion on the power cable connector. 
• 
check for damaged power cable. 
• 
check battery for proper voltage output (10.8 to 31.2 V). 
there is no response 
when a key is pressed 
• 
turn off and on the power. If there still is no response the key may 
be faulty. Request service. 
 
7.5.2 Radar 
GD-1900C requires a network radar. 
Radar troubleshooting 
If… But…  Then… 
you pressed the 
[POWER/BRILL] key and the 
RADAR TX soft key to show 
the radar picture   
nothing appears on the 
display 
• 
check that the antenna cable is 
firmly fastened. 
• 
check if radar source is correct.
marks, legends appear   
no echo appears 
• 
check Tx fuse in power cable. 
If it is blown, replace it. 
the picture is not updated or 
it freezes 
— 
• 
check antenna cable. 
• 
for freeze up, turn the display 
unit on and off again. 
tuning is adjusted 
sensitivity is poor 
• 
magnetron may need to be 
replaced. Contact your dealer. 
the range is changed 
radar picture does not 
change 
• 
try to hit the [+] and [-] keys 
again. 
• 
turn the display unit off and on 
again. 
there is poor discrimination in 
range 
— 
• 
adjust A/C SEA. 
the true motion presentation 
is not working properly 
 
• 
reselect true motion mode. 
• 
check if heading and speed are 
input. 
the range rings are not 
displayed 
— 
• 
hit the RADAR DISPLY and 
RINGS soft keys to display 
them.