IMPORTANT: Vent-free gas log heaters add 
moisture to the air. Although this is beneficial, 
installing  firebox  in  rooms  without  enough 
ventilation air may cause mildew to form from 
too  much  moisture.  See  Air  for  Combustion 
and Ventilation
, page 5. 
IMPORTANT: Make sure firebox is level. If fire-
box is not level, log set will not work properly. 
Note: Your firebox is designed to be used in zero 
clearance installations. Wall or framing material can 
be placed against any exterior surface on the rear, 
sides, top or bottom of your firebox, except where 
standoff spacers are integrally attached. If standoff 
spacers are attached to your firebox, these spac-
ers can be placed directly against wall or framing 
materials. Use the dimensions shown for rough 
opening to create the easiest installation.
Use  dimensions  shown  for  rough  openings 
to create the easiest installation (see Built-In 
Firebox Installation
, page 9).
INstAllAtIoN cleARANces
  WARNING:  maintain  the 
minimum clearances. if you can, 
provide greater clearances from 
floor, ceiling and adjoining wall.
Carefully  follow  these  instructions. This  will 
ensure safe installation.
Minimum wall and Ceiling Clearances (see 
figure 4)
A.  Clearances  from  the  side  of  fireplace 
cabinet to any combustible material and 
wall should follow diagram in Figure 4.
 
Example: The face of a mantel, bookshelf, 
etc. is made of combustible material and 
protrudes 3 
1
/
2
" from the wall. This com-
bustible material must be 4" from the side 
of the fireplace cabinet (see Figure 4).
B.  Clearances from the top of firebox opening 
to ceiling should not be less than 42".
C.  When firebox is installed on carpeting or 
other  combustible  material,  other  than 
wood flooring, firebox should be installed 
on a metal or wood panel extending the 
full width and depth of enclosure.
D.  Clearances from bottom of firebox to the 
floor is 0".
These fireboxes can be installed as freestanding 
units against a wall with the approved, optional 
cabinet mantels (s
ee Accessories, page 14
) or as 
a built-in unit. Clearances are the same for either 
installation method. 
INSTALLATION
Continued
Figure 4 - Minimum Clearance for 
Combustible to Wall 
*Minimum 16" from Side Wall 
*
 Caution: Do not install fire-
box directly on carpet or vinyl.
Example
mantel clearances for built-In Installation
If placing custom mantel above built-in firebox, 
you must meet the minimum allowable clear-
ance between mantel shelf and top of firebox 
opening shown in Figure 5, page 9. These are 
the minimum allowable mantel clearances for 
a safe installation. Use larger clearances wher-
ever possible to minimize the heating of objects 
and materials placed on the mantel.
  cAutIoN:  do  not  allow 
the  vent-free  gas  log  heater 
to touch or extend beyond the 
fireplace screen.
notiCe:  surface  temperatures 
of adjacent walls and mantels be-
come hot during operation. walls 
and  mantels  above  the  firebox 
may  become  hot  to  the  touch. 
if installed properly, these tem-
peratures meet the requirement 
of the national product standard. 
Follow all minimum clearances 
shown in this manual.
NotIce: If your installation does 
not meet the minimum clearances 
shown, you must do one of the 
following:
•  raise the mantel to an accept-
able height
•  remove the mantel