FMI pfs us vshrp26m Benutzerhandbuch

Seite von 28
www.fmiproducts.com
125311-01A
14
OPERATION 
in the safety information, column 1. If you 
don’t smell gas, go to the next step.
6. 
Thermostat  Models: Turn control knob 
counterclockwise 
  to  the  PILOT 
position. Press in control knob for five (5) 
seconds. 
 
Manual Models: Press in and turn control 
knob counterclockwise 
 to the PILOT 
position. Keep control knob pressed in for 
five (5) seconds. 
7.  With control knob pressed in, push down 
and release ignitor button. This will light 
pilot. The pilot is attached to the front of 
burner.  Note: You  may  be  running  this 
heater for the first time after hooking up to 
gas supply. If so, you may need to press 
in control knob for 30 seconds or more. 
This will allow air to bleed from the gas 
system. If needed, keep pressing ignitor 
button until pilot lights. If ignitor does not 
light pilot, refer to Troubleshooting, page 
18 or contact a qualified service person 
or gas supplier for repairs. Until repairs 
are made, light pilot with match. To light 
pilot  with  match,  see  Manual  Lighting 
Procedure, page 16.
8.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob.
 
• If control knob does not pop out when 
released, contact a qualified service per-
son or gas supplier for repairs.
 
Note:  If  pilot  goes  out,  repeat  steps  4 
through  7.  Wait  one  (1)  minute  before 
lighting pilot
9.  Turn control knob counterclockwise 
 
to desired heating level. The main burner 
should  light.  Manual  control  heaters 
should be used in locked positions.
Figure 20 - Control Knob in the OFF 
Position for Thermostat Models
Figure 19 - Control Knob in the OFF 
Position for Manual Control Models
FOR YOUR SAFETY 
READ BEFORE LIGHTING
 WARNING: If you do not fol-
low these instructions exactly, 
a  fire  or  explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must 
be  lighted  by  hand.  When  lighting 
the  pilot,  follow  these  instructions 
exactly.
B.  BEFORE  LIGHTING  smell  all  around 
the appliance area for gas. Be sure to 
smell next to the floor because some 
gas is heavier than air and will settle 
on the floor.
 
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do 
not use any phone in your building.
• Immediately  call  your  gas  supplier 
from a neighbor’s phone. Follow the 
gas supplier’s instructions.
• If you cannot reach your gas supplier, 
call the fire department.
C.  Use only your hand to push in or turn the 
gas control knob. Never use tools. If the 
knob will not push in or turn by hand, don’t 
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted 
repair may result in a fire or explosion.
D.  Do not use this appliance if any part has 
been  under  water.  Immediately call a 
qualified service technician to inspect 
the appliance and to replace any part of 
the control system and any gas control 
which has been under water. 
LIGHTING 
INSTRUCTIONS
1.  STOP!  Read  the  safety  information 
above.
2.  Make  sure  equipment  shutoff  valve  is 
fully open.
3.  Turn off any electric power to the appli-
ance if service is to be performed.
4.  Turn control knob clockwise 
 to the 
OFF position.
5.  Wait five (5) minutes to clear out any gas. 
Then  smell  for  gas,  including  near  the 
floor. If you smell gas, STOP! Follow “B” 
Control 
Knob
O
OT
 
Control 
Knob