Installation Specifications
Installation Planning
 WARNING
Observe all governing codes and ordinances during plan-
ning and installation. Contact your local building depart-
ment for further information.
 IMPORtANt
•  Locate the junction box so that the oven may be easily 
disconnected in the event that it needs to be removed 
from the wall completely for service.
•  If the oven is not installed level it may deliver poor or 
inconsistent baking results.
•  Carefully check the location where the oven is to be 
installed. The oven should be placed for convenient 
access. Make certain that electrical power, meeting the 
specifications on page 4, can be provided in the 
selected location.
•  Dacor recommends installing the electrical junction box 
in the one of the locations shown.
1 1/2” (3.8 cm) thick typical counter
1” (2.5 cm) min.
to combustible floor
3/4” (1.9 cm)
support platform
Recommended
electrical
location
4” typical toe kick
36” typ.
(91.4 cm)
29” (73.4 cm)
min. to
combustibles
B
C
Minimum interior cabinet depth* - standard installation: 24” (61.0 cm) min. 
 
 
 
 
- flush installation: 25 3/8” (66.0 cm) min.
* Includes spacing required 
for proper ventilation
•  Install the junction box in a location that allows the 
oven to be removed from the cut out for service without 
being disconnected.
•  Plan the installation so that all minimum clearances 
are met or exceeded. Dimensions shown provide mini-
mum clearances, unless otherwise noted. Be certain 
that proper clearance is provided for the oven door 
when it is in the open position according the Product 
Dimensions.
•  Cabinet cutout dimensions must be used as indicated. 
The specified minimum cabinet depth and width must 
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
•  All contact surfaces between the appliance and the 
cabinet must be solid and level. 
•  Provide a platform within the cabinet to support the 
oven. It must be installed level and straight. The top 
edge of the platform must be flush with the cut out at 
the front of the cabinet. There are no provisions to level 
the oven after it has been installed. 3/4” (1.9 cm) thick 
plywood is recommended.
Model 
Number
 (A) Minimum Cabinet 
Width
 (B) Minimum 
Cutout Width
 (C) Minimum 
Cutout Height
Standard
Flush
Standard
Flush
Standard
Flush
DYO130B
30” 
(76.2 cm) 
31”
(78.7 cm) 
28 3/8” to 29” 
(72.1 cm to  
73.7 cm)
30” 
(76.2 cm)
27” 7/16” to 28 1/4”  
(69.7 cm to 
71.8 cm)
28 7/8” 
(73.3 cm) 
DYO130S
DYOV130B
DYO230B
30”
(76.2 cm) 
31”
(78.7 cm) 
28 3/8” to 29” 
(72.1 cm to  
73.7 cm)
30” 
(76.2 cm)
50 3/8” to 50 3/4” 
(128.0 cm to 
128.9 cm)
51 5/8” 
(131.1 cm)
DYO230S
DYOV230B
Cabinet Dimensions
Single Wall Oven - Installed Under Counter
Cabinet tolerances: +1/16 (1.6 mm), -0, unless otherwise stated.