DSC power864 Benutzerhandbuch

Seite von 36
18
Zone Light
Type Of Trouble
7
Low zone battery. This trouble is generated when a wireless device has a 
low battery. This trouble only applies if you have wireless devices 
installed on your system. Press [7] one, two, or three times to view which 
devices are experiencing battery failure. The following will occur:
Keypad beeps: Keypad displays:
Press [7]1
Zones with low batteries 
Press [7] again2 Handheld keypads with low batteries 
Press [7] again3 Wireless keys with low batteries.
8
Loss of time on system clock. To set the system time, follow the instruc-
tions in “Setting the Time and Date” on page 21.
2. To exit trouble viewing, press 
.
Viewing the 
Event Buffer 
from an 
LCD5500Z 
Keypad
The event buffer will show you a list of the last 256 events that have occurred on your sys-
tem. You must use an LCD5500Z keypad to view the event buffer.
1. Press  
[master 
code]. 
2. To select Event Buffer viewing, press 
3. The keypad will display the event number, partition or area, and the time and date. Press 
 to switch between this information and the event details. 
4. Use the 
 keys to scroll through the events in the buffer. 
5. To exit event buffer viewing, press 
.
Testing Your 
System
Testing Your Keypad Sounder and Siren 
The System Test provides several system tests, and a two-second check of the keypad 
sounder and bell or siren. 
1. Press  
[Master 
Code] 
.
2. The following will occur: 
- The system activates all keypad sounders and bells or sirens for two seconds -- All key-
pad lights turn ON.
-  LCD5500Z keypads will light all pixels 
- The Ready, Armed, and Trouble LED’s will flash for the duration of the test
3. To exit the function menu, press 
Testing Your Entire System
All smoke detectors in this installation must be tested by your smoke detector installer or 
dealer once a year to ensure they are functioning correctly. It is the user’s responsibility to 
test the system weekly (excluding smoke detectors).  Ensure you follow all the steps in the 
‘Testing Your System’ section above.
NOTE:
 Should the system fail to function properly, call your installation company 
for service immediately. 
1. Prior to testing, ensure that the system is disarmed and the Ready light is on.
2. Press 
 and close all zones to return the system to the Ready state.
3. Perform a System Test by following the steps in the previous section.
4. To test the zones, activate each detector in turn (e.g., open each door/window or walk 
in motion detector areas).