Desa csbpt Benutzerhandbuch

Seite von 24
www.desatech.com
111487-01E
16
TROUBLESHOOTING
 WARNING: Turn off heater and let cool before servicing. Only a 
qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note:
 All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor  cable  pinched  or 
wet
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned 
wrong
1. Gas supply turned off or equip-
ment shutoff valve closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air in gas lines when installed
5. ODS/pilot is clogged
6. Gas regulator setting is not 
correct
7. Depleted  gas  supply  (pro-
pane/LP only)
1. Control  knob  not  fully 
pressed in
2. Control knob not pressed in 
long enough
3. Equipment shutoff valve not 
fully open
4. Pilot  flame  not  touching 
thermocouple, which allows 
thermocouple to cool, caus-
ing pilot flame to go out. This 
problem could be caused by 
one or both of the following:
  A) Low gas pressure
  B) Dirty or partially clogged  
ODS/pilot 
5. Thermocouple  connection 
loose at control valve 
6. Thermocouple damaged
7. Control valve damaged
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry
3. Replace ignitor cable
4. Replace piezo ignitor 
5. Replace pilot assembly
6. Replace pilot assembly
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while in 
PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Clean ODS/pilot (see Cleaning 
and Maintenance, page 14) or 
replace ODS/pilot assembly
6. Replace gas control
7. Contact local propane/LP gas 
company
1. Press in control knob fully
2. After ODS/pilot lights, keep con-
trol knob pressed in 30 seconds
3. Fully open equipment shutoff 
valve
4. A)  Contact  local  natural  or 
propane/LP gas company
 
  B)  Clean  ODS/pilot  (see 
Cleaning  and  Maintenance
page 14) or replace ODS/pilot 
assembly 
5. Hand tighten until snug, then 
tighten 1/4 turn more
6. Replace pilot assembly
7. Replace control valve
OBSERVED PROBLEM
When ignitor button is pressed, 
there is no spark at ODS/pilot
When ignitor button is pressed, 
there  is  spark  at  ODS/pilot  but 
no ignition
ODS/pilot lights but flame goes 
out  when  control  knob  is  re-
leased