Desa cspbnt Benutzerhandbuch

Seite von 24
www.desatech.com
111487-01E
8
INSTALLATION
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
 WARNING: A qualified ser-
vice person must install heater. 
Follow all local codes.
 WARNING: Never install the 
heater
•  in a bedroom or bathroom
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing  or  other  flammable 
objects are less than 42 inches 
from the front, top or sides of 
the heater
•  in high traffic areas
•  in windy or drafty areas
 CAUTION: This heater cre-
ates  warm  air  currents.  These 
currents move heat to wall sur-
faces  next  to  heater.  Installing 
heater next to vinyl or cloth wall 
coverings  or  operating  heater 
where impurities (such as, but 
not limited to, tobacco smoke, 
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in 
the air exist, may discolor walls 
or cause odors.
IMPORTANT:
 Vent-free heaters add moisture to 
the air. Although this is beneficial, installing heater 
in rooms without enough ventilation air may cause 
mildew to form from too much moisture. See Air 
for Combustion and Ventilation, page 5.
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for 
your unit. If your stove heater gas type is different 
from your house gas type, do not install heater. 
Call dealer where you bought heater for proper 
type heater.
  WARNING:  This  appliance 
is equipped for (natural or pro-
pane/LP) gas. Field conversion 
is not permitted.
CLEARANCES TO COMBUSTIBLES 
(Vent-Free Operation Only)
  WARNING:  Maintain  the 
minimum clearances. If you can, 
provide greater clearances from 
floor, ceiling and adjoining side 
and back walls.
Carefully follow the instructions below. This stove 
is a freestanding unit designed to set directly on the 
floor. DO NOT place stove directly on carpeting, 
vinyl tile or any combustible material other than 
wood. The stove must be set on a metal or wood 
panel extending the full width and depth of the 
stove for these floor coverings. Important: You 
must maintain minimum wall and ceiling clear-
ances during installation. The minimum clearances 
are  shown  in  Figure  5,  page  9.  Measure  from 
outermost point of stove top.
Minimum Wall and Ceiling Clearances  
(see Figure 5, page 9)
A.  Clearances from outermost point of stove top 
to any combustible side wall should not be 
less than 12 inches.
B.  Clearances from outermost point of stove top 
to any combustible back wall should not be less 
than 6 inches (includes corner installations).
C.  Clearances from the stove top to the ceiling 
should not be less than 48 inches.