Data Ports
Applicator Interface Connector
57518L-001 Rev. 1
3/18/05
170PAX4 Maintenance Manual
353
Jumper Configurations for +5 V I/O Applicator Interface Board
 shows the pin and jumper configurations for pins 1 and 2 in +5 V I/O operation.
Jumpers J4 and J5 are used together to produce isolated or non-isolated modes of operation for 
applicator input and output control signals. J4 configures the +5 V source for the optoisolator 
circuits, and J5 configures the ground. For proper operation, when J4 is installed, J5 must be 
installed, and when J4 is removed, J5 must be removed.
Table 47 • Pin 1 and Pin 2 Jumper Configurations
Pin No.
Non-Isolated
Isolated
1
J5 In
I/O ground is connected to the 
Applicator Interface Circuit 
Ground.
J5 Out
I/O ground is disconnected from the Applicator Interface 
Circuit Ground. Ground for the applicator interface 
optoisolator circuits is provided externally to this pin.
2
J4 In
+5 V I/O is connected to the 
Applicator Interface Circuit +5 V 
Supply.
J4 Out
+5 V I/O is disconnected from the Applicator Interface 
Circuit +5 V Supply. The +5 V for the applicator 
interface optoisolator circuits is provided externally to 
this pin.