INSTEON Limited Warranty – INSTEON warrants to original consumer of this product for a period of 2 years from 
date of purchase, this product will be free from defects in material and workmanship and will perform in substantial 
conformity with its Owner's Manual. Warranty shall not apply to defects caused by misuse or neglect. 
Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012 
INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845, www. Insteon.com 
 
 
Quick Start Guide
  
SwitchLinc™ Dimmer 240V, 50/60Hz (Dual-Band) 
INSTEON
® 
Remote Control Dimmer Switch
 
Model: 2478D 
About SwitchLinc Dimmer 240V, 50/60Hz 
Congratulations on purchasing the SwitchLinc Dimmer 240V. This 
internationally-compatible version of our bestselling SwitchLinc Dimmer 
features automatic 50/60Hz detection of the AC power frequency and flexible 
100 - 277VAC support, allowing operation in a variety of electrical 
environments.  
Preparation 
Installation should be performed only by a qualified electrician or by a 
homeowner who is familiar and comfortable with electrical circuitry. If you have any questions regarding installation, we 
suggest consulting an electrician. If you have any questions regarding setup, contact the INSTEON Support Line. 
What’s in the box? 
 
SwitchLinc Dimmer   
 
•     Four wire nuts 
Tools Needed 
 
Slotted screwdriver   
 
•     Phillips screwdriver 
 
Wire cutter / stripper  
 
•     Voltage Meter 
Installation 
1)  Turn off circuit breaker(s) or remove fuse(s) feeding wall box 
2)  Use a voltage meter to verify that power is off 
3)  Remove wallplate from switch and unscrew switch you are replacing and 
gently pull out 
4)  Turn breaker(s) back on 
5)  Use a voltage meter to identify line and load wires connected to switch 
6)  Identify Neutral and ground wires 
7)  Turn breaker(s) back off 
8)  Connect wires as indicated. Confirm firm attachment with no exposed wire. 
9)  Gently place SwitchLinc into wall box, orienting unit with the LED bar on left 
10)  Screw SwitchLinc into place 
11)  Turn breaker(s) back on 
SwitchLinc LED bar and connected light will turn on 
12)  Verify SwitchLinc is working properly by tapping SwitchLinc’s paddle 
turning light (load) on and off 
13)  Reinstall the wallplate 
 
Note: For 3-way/4-way circuit installations, refer to the Owner’s Manual 
 
Note: When mounting in a multiple-ganged junction box, SwitchLinc 
Dimmer is de-rated for 200-watts less for each immediately adjacent 
dimmer installed. For example, 600W load control becomes 400W with 
another dimmer to the immediate right or left. Use a triple-gang box with 
a mechanical switch in the center to avoid de-rating.
SwitchLinc Wire  Wall Box Wires 
Bare copper 
Ground 
(commonly bare, 
green wire or 
green screw) 
White 
Neutral 
(commonly 
white) 
Red 
Load  
(light, fan, etc.) 
Black 
Line 
(100 - 277VAC 
to Ground) 
LED bar 
brightness 
indicators 
Paddle top 
(on/brighten) 
Paddle bottom 
(off/dim) 
Set button