Press Mode to step between menu items (sub-mode number will appear on top of the screen). 
o
 
Sub-mode 01: Display LED on-time select (default is 10 seconds) 
o
 
Sub-mode 02: Humidity low setpoint (default is 30%) 
o
 
Sub-mode 03: Humidity high setpoint (default is 90%) 
o
 
Sub-mode 04: Temperature format select (default is Fahrenheit) 
o
 
Sub-mode 05: Internal or External temperature sensor (default is Internal) 
o
 
Sub-mode 06: Beep on button press (default is off) 
o
 
Sub-mode 07: Button lock (default is off) 
o
 
Sub-mode 08: Programming lock (default is off) 
o
 
Sub-mode 09: Activation delay (default is 5 minutes) 
 
2)  Press the Up or Down arrow to change a setting 
• 
Sub-mode 01: LED backlight ON time (10–second default)  
a.  Tap up or Down arrow to step between OFF, 10 seconds, 60 seconds and ON 
Note: Do not set to ON unless you are connected to a power supply or the batteries will 
drain very rapidly. 
 
 
 
• 
Sub-mode 02: Humidity low setpoint (humidification, 30% default) 
a.  Up arrow = Increase humidity % setpoint 
b.  Down arrow = Decrease humidity % setpoint 
c.  Press and hold arrow buttons to scroll 
d.  Range = 0 to 79% (humidity high setpoint will automatically adjust to be +20% than 
humidity low setpoint) 
 
 
 
• 
Sub-mode 03: Humidity high setpoint (dehumidification, 90% default) 
a.  Up arrow = Increase humidity % setpoint 
b.  Down arrow = Decrease humidity % setpoint 
c.  Press and hold arrow buttons to scroll 
d.  Range = 20 to 99% (cannot come within 20% of humidity low setpoint) 
 
 
 
• 
Sub- mode 04: Temperature format select (C or F, F default) 
a.  Up arrow = C 
b.  Down arrow = F