Vent Installation
V
enting
:
This appliance has been tested and listed as a direct­vent heater 
system by OMNI­Test Laboratories, Portland, Oregon and is rec­
ommended for use with Security™ Secure Vent pipe*.
Important:
•  Read all instructions carefully before starting the installation. 
Failure to follow these instructions may create a fire or other 
safety hazard and will void the warranty. Be sure to check for 
specific clearances to combustible requirements on Page 9
Do not extend the venting system vertically or horizontally in 
excess of the distance prescribed on Page 16
. Consult your 
local building codes before beginning the installation.
•  Always maintain the proper air spaces between the vent pipe 
and nearby combustibles to prevent a fire hazard. Do not fill 
air spaces with insulation. Be sure to check the vent termina­
tion clearance requirements from decks, windows, soffits, gas 
regulators, air supply inlets and public walkways, as specified 
in these installation instructions on Page 17 and local building 
codes.
•  This gas appliance and vent system must be vented directly 
to the outside of the building and never be attached to a 
chimney serving a separate solid fuel or gas-burning appli-
ance
. Each direct­vent gas appliance must use its own separate 
vent system. Common vent systems are prohibited.
•  This appliance is recommended for use with Security™ Secure 
Vent pipe*. The appliances and vent manufacturers warranties 
will be voided and serious fire, health, or other safety hazards 
may result from any of the following actions:
­  Installation of any damaged direct­vent component.
­  Unauthorized modification of the direct­vent system.
­  Installation of any vent component part not approved or 
manufactured by the approved vent manufacturer.
­  Installation  other  than  as  instructed  by  Lennox  Hearth 
Products and vent manufacturers instructions.
Residential and Mobile Home Installations:
These are the minimum pieces required. Other parts may be required for 
your particular installation.
Minimum Components for Horizontal Installation:
Horizontal Termination Kit which includes:
•   1  6­5/8”x 6” Black Pipe
•   1  Riser Vent Terminal 
•  1  Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
•   1  Decorative Wall Trim (black)
•  1  Tube Mill­Pac
•  Screws
Optional Components:
•   45º Elbow
•  Vinyl Siding Shield for Riser Vent Terminal
•  Vent Guard
•  Snorkel Termination (36”)
•  Snorkel Termination (14”)
•  Wall Penetration Heat Shield
Vent Considerations:
Twist-lock procedure: 
 Four indentations on female ends of pipes and 
fittings are designed to slide straight onto male ends of adjacent pipes 
and fittings by orienting the four pipe indentations so they match and 
slide into the four entry slots. Push pipe sections completely together, 
then twist­lock one section clockwise approximately one­quarter turn 
until the two sections are fully locked. The female locking lugs will not 
be visible from the outside on the pipe or fittings. They may be located 
by examining the inside of the female ends.
Supports: 
 Horizontal runs of vent must be supported every 3 feet.  Wall 
straps are available for this purpose.
Pipe Sealing: 
 If Simpson Dura­Vent pipe is used, the pipe must be sealed 
as follows: seal both the inner and outer pipes with a high temperature 
silicone sealant rated for at least 600ºF (commonly know as “RTV”). Run 
a 1/8” bead of silicone around outside of male end of outer sleeve. Run 
a 1/8” bead of silicone about 1/4” from the end of the male inner pipe, 
which is found in the pipe to be attached above. Twist­lock the pipes or 
fittings together.
* Other approved chimney brand is Simpson Dura­Vent DV­GS.
Figure 19
Sealant
Female 
Locking 
Lugs
Male 
Locking 
Lugs