LST BC06-2EXT Benutzerhandbuch

Seite von 4
0786–CPD–20300
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED
BC06EXT_DBL_LST_EN_0826.PDF • PAGE 1
A
Building Safety. Building Security.
•   For application in single-zone 
extinguishing systems
•   4 detector zones in conventional 
technology
•   Differentiation between the activation 
of automatic detectors and manual 
call points on the same detector line
•   Clear display and operation on the 
panel front
•   Tested to EN 54-2, -4, EN 12094-1 by 
VdS
Already in the basic version the combined Fire/Extingu-
ishing Control Panels BC06-1EXT and BC06-2EXT are 
equipped with four detector lines and the Extinguishing 
Board EXB1-1 and, owing to its sophisticated factory 
settings, are immediately ready for operation. This al-
lows for quick and effi cient application of the product.
The conventional technology allows for the connection 
of automatic and non-automatic fi re detectors as well 
as a wide range of special detectors with contact out-
put. Alarms from manual call points and from automatic 
detectors that are connected together to one detector 
line can be differentiated and thus evaluated differently 
by the fi re/extinguishing control panel, by means of an 
optional coding module.
Thanks  to  the  two  auxiliary  inputs  whose  parameters 
can be freely set as well as the eight open-collector out-
puts, manifold tasks in the fi eld of fi re alarm technology 
can be realised.
The  optional  evacuation  function  serves  for  the  actu-
ation of alarming devices independent from activated 
alarms.
Thanks  to  the  integrated  extinguishing  module,  the 
BC06  can  be  used  as  an  extinguishing  control  panel 
according to EN 12094-1 with one fl ooding zone. The 
module provides appropriate inputs and outputs for con-
trolling and monitoring a fl ooding zone. The display and 
operating elements that are necessary for the status 
indication and the operation of the extinguishing module 
are integrated into the keypad.
A  printer  for  the  event  log  can  be  connected  via  the 
optional Serial Interface Modul SIM06-1.
The  Fire/Extinguishing  Control  Panel  BC06-2EXT  dif-
fers from the BC06-1EXT by the additionally integrated 
 4-digit electronic alarm counter.
Fire is a permanent threat to life and property. There-
fore, immediate response to a fi re is imperative. The 
main  objective  of  the  Fire  Detection  Control  Panel 
 Series BC06 is to alarm and to react in time and, con-
sequently, save lives and protect property. For decades 
LST have focused their aims to undertaking unrivaled 
efforts in order to realise new innovations in the security 
area. Research, development and production are loca-
ted within LST premises, thus guaranteeing fl exible and 
reliable individual solutions.
Using a powerful processor system and a large number 
of integrated functions, the Fire/Extinguishing Control 
Panels  Series  BC06  ensure  topmost  effi ciency  and 
speed –  prerequisites  for  saving  lives  and  minimising 
damage to property.
Description