Jacuzzi j - 200 j - 230 Benutzerhandbuch

Seite von 64
J-200
14.0  error Conditions/error Messages
Your spa has a self-diagnostic control system. The system will 
automatically display the following if a problem is detected.
14.1  summer logic (spas with Circulation pump 
option)
When the actual spa water temperature reaches up to 2°F 
(1°C) above the set temperature, the spa goes into “summer 
logic.” The 24-hour circulation pump will turn off automatically 
to avoid adding additional heat to the water, eventually creating an 
overheat condition. This setting is not user-programmable.
note: The summer logic does not take effect until the spa water 
temperature reaches 95°F (35°C). This condition is more likely in 
excessively hot weather. Remember, the spa’s ability to cool is directly 
affected by the ambient temperature. An excessively hot ambient 
temperature may prevent the spa from cooling down because it’s 
fully insulated construction is designed to retain heat and to minimize 
operating costs.
14.2  panel Displays Col
Cool Condition - Temperature has dropped 20°F (11°C)  
below the current set temperature. Jets pump 1, (or 
optional circulation pump) and the heater have been activated to bring 
the temperature to within 15°F (8°C) of the set temperature. No 
corrective action is required! 
note: This condition is common during first time fill ups or during refills 
since tap water is often very cold.
14.3  panel Displays ICe
Freeze Protection - A potential freeze condition has been 
detected. No action is required. Jets pump (or optional 
circulation pump) and heater will operate to circulate and warm water 
through the plumbing until spa is out of DANGER. See “Winterizing” 
14.4  panel Displays sn1
Open sensor (heater is disabled) or shorted sensor (spa is  
deactivated). The high-limit temperature sensor is not 
functioning. Contact your authorized Jacuzzi dealer or qualified service 
technician.
14.5  panel Displays sn2
Open or shorted sensor (heater disabled). The temperature  
sensor is not functioning. Contact your authorized Jacuzzi 
dealer or qualified service technician.
40