Whirlpool 1187680 Benutzerhandbuch

Seite von 28
8
AIR CONDITIONER USE
Operating your air conditioner properly helps you to obtain the 
best possible results. 
This section explains proper air conditioner operation.
IMPORTANT: 
If you turn off the air conditioner, wait at least 3 minutes 
before turning it back on. This prevents the air conditioner 
from blowing a fuse or tripping a circuit breaker.
Do not try to operate your air conditioner in the cooling mode 
when outside temperature is below 66°F (19°C). The inside 
evaporator coil will freeze up, and the air conditioner will not 
operate properly.
NOTES: 
In the event of a power failure, your air conditioner will 
operate at the previous settings when the power is restored.
If the electronic control will not respond to touch pad or 
remote control commands, it is necessary to unplug the unit 
from the electrical outlet for 5 seconds before plugging 
back in.
Starting Your Air Conditioner
Models without heat
Models with heat
1. Press POWER to turn on air conditioner.
NOTE: When the unit is turned on, it will display the previous 
settings for the mode, fan speed and temperature.
2. Choose mode. See “Mode.”
3. Choose fan speed. See “Fan Speed.”
4. Choose temperature. See “Temperature.”
Mode
1. Press and hold MODE.
2. Choose COOL, FAN, HEAT (on some models) or POWER 
SAVER.  
Cool—Cools room. Press FAN SPEED to choose fan 
speed. Then adjust the temperature by pressing the up or 
down arrow buttons.
Fan—Operates the fan at Low, High or Turbo (on some 
models) speed, without cooling. 
Power Saver—The fan will switch from the set fan speed 
to LOW whenever the compressor turns off in response to 
the set temperature. When the compressor cycles back 
on, the fan will return to the set fan speed.
Heat (on some models)—The unit will circulate and heat 
the air.
When heater is powered off, low fan will automatically 
stay on and run for 60 seconds. Low Fan indicator light 
will blink while the low fan is operating.