SERVICE CONNECTIONS
ELECTRIC HEAT, VSX24E
FIG. 10
LEGEND
A.
JUNCTION BOX:  J.I.C. 6X6X4 FOR ELECTRICAL SUPPLY CONNECTION FOR
HEAT.
B.
ELECTRICAL CONNECTION FOR CONTROLS:  120V/60HZ/1PH/300 WATT
MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED.  (NOT
PROVIDED IF A STEP DOWN TRANSFORMER IS FURNISHED.)
C.
COLD SUPPLY WATER CONNECTION:  
1
4
” NPT FOR BOILER DRAIN AND
COMPARTMENT DRAIN COLD WATER CONDENSERS.
D.
DRAIN:  COMPARTMENT, BOILER AND EXHAUST GROUP APPROXIMATELY
3
1
2
” IN DIAMETER.  (PROVIDE AN OPEN AIR GAP TYPE DRAIN DIRECTLY
UNDER UNIT FRAME.  DO NOT CONNECT SOLIDLY TO ANY DRAIN
CONNECTION.)
NOTE:  DIMENSIONS WHICH LOCATE THE ABOVE CONNECTIONS HAVE A
TOLERANCE OF 
±
 3 IN. (
±
 75 MM).  NORMAL DIMENSIONS ARE IN INCHES.
DIMENSIONS IN ( ) ARE IN MILLIMETERS.
EQUIPMENT CLEARANCES
TO COMBUSTIBLE CONSTRUCTION
REAR:  2 IN. MIN. (50 MM.)