barker--williamson traps & loading coil usage Benutzerhandbuch

Seite von 2
Barker & Willamson traps are ruggedly constructed in a weatherproof plastic enclosure with stainless steel hardware.
Loading coils are wound on top of weatherproof plastic, and covered with a heat shrink sleeve.  They will provide many
years of trouble free service.  This guide will assist  in design and usage of these items.  Remember that all short dipole
antennas will have a bandwidth narrower than a full size half wave dipole.  Therefor, an antenna tuner may be helpful.
Installation is best done as an inverted Vee.  Satisfactory results may be obtained with the center as low as 20 feet, however
30 feet or more is recommended.  If a flat top installation is desired, it is best to have the center supported due to the weight
of the traps/loading coils and coaxial feed line.
Assemble the sections of the antenna together paying attention to the figures.  The wire segment lengths shown in the table
are your starting point for tuning the antenna.  When you cut the wire, leave plenty of excess for making connection and
lengthening if necessary.  Make sure that you make temporary connections as shown in figure 3.  Raise your antenna, and
check the VSWR on the highest frequency band first.  If the resonant frequency is low, shorten the wire segments.  If it
is high, lengthen the wires.  After the desired frequency is achieved,  make permanent attachment for these segments as
shown in figure 2, trimming off excess wire.  Repeat this procedure for each band, going from highest to lowest frequency.
WARNING
Outdoor antennas and lead-in conductors from antenna to building shall not cross over electric light or power circuits
and shall be kept well away from all such circuits so as to avoid the possibility of accidental contact. Where proximity
to electric light or power service conductors of less than 250 volts cannot be avoided, the installation shall be such so
as to provide a clearance of at least 2 feet.  Where practical, antenna conductors shall be installed so as to not cross
under electric light or power conductors.
BARKER & WILLIAMSON
603 CIDCO   ROAD
COCOA, FL 32926
321-639-1510
12/00
MODEL  TR TRAPS
MODEL LC LOADING COILS
Power Rating:  1000W PEP
500W Output
Figure 3:  Temporary hookup for
tuning.  Loosely twist and tape ends in.
Figure 2:  Permanent hookup.  After passing
through the eybolt, wrap the wire around itself
5 times before soldering to the terminal.
Figure 1:   Wire and trap arrangement (one side only).  Refer to table.